Dayton
Dayton 48C176 Digital Temperature Interlock 8in Steel 0.2V
Digital temperature interlock with steel housing and two sensors rated for 15 A full-load current
- Digital interlock prevents overheating with two sensors
- UL and C-UL listed plus NSF Standard 2 certified
- Steel enclosure measures eight inches tall by four inches wide
- Includes wiring diagram and electrical control for quick setup
- Operates at 0.2 volts AC with 15 amp full-load current
Dayton 48C176 Digital Temperature Interlock
This Dayton 48C176 is a digital temperature interlock designed for machinery and machine-shop environments where precise thermal monitoring is required. It suits maintenance technicians and plant engineers who need a compact, steel-housed control device rated for 0.2 V AC nameplate voltage.
Steel enclosure with two sensors and UL Quick Seal
The steel body measures 8 in high by 4 in wide by 4 in deep and carries UL and C-UL listing plus NSF Standard 2 certification. Two integrated temperature sensors feed the electrical control module, while the included wiring diagram and UL-approved Quick Seal simplify panel mounting and daily inspection routines.
15 A full-load current rating for circuit protection
The interlock handles up to 15 A full-load current, making it the decisive specification for matching the device to motor-starter or contactor circuits. Buyers whose applications exceed this current level must select a higher-rated interlock instead.
Highlights
- Digital interlock prevents overheating with two sensors
- UL and C-UL listed plus NSF Standard 2 certified
- Steel enclosure measures eight inches tall by four inches wide
- Includes wiring diagram and electrical control for quick setup
- Operates at 0.2 volts AC with 15 amp full-load current
Specifications
| Brand | DAYTON |
|---|
Questions about this item
What does the 0.2 V AC nameplate voltage mean for the control circuit?
The interlock's control circuit operates at 0.2 V AC, so it must be wired to a compatible low-voltage supply; it cannot connect directly to line voltage.
What are the 8 in height and 4 in width and depth dimensions for?
The enclosure measures 8 in high by 4 in wide by 4 in deep, so the mounting surface must accommodate that footprint and clearance for wiring.
How are the two temperature sensors and electrical control wired during installation?
Follow the included wiring diagram to connect both sensors and the control module; the common error is reversing the sensor leads, which prevents the interlock from tripping.