Bussmann
Bussmann TCFH30N Finger Safe Fuse Block J UL Class 600V AC/300V DC
Finger-safe fuse block for Class J and CF fuses up to 30 A, 600 V AC or 300 V DC, DIN-rail mount with box-lug terminals for 18 to 8 AWG wire
- Finger-safe design protects against accidental contact
- Accepts 18 to 8 AWG wire for versatile connections
- DIN rail mounting enables quick panel installation
- UL Listed and CSA Certified for code compliance
- Rated 600V AC and 300V DC for industrial circuits
Class J Fuse Block 0-30 A
The Bussmann TCFH30N is a single-pole Class J fuse block rated 600 V AC and 300 V DC for fuses up to 30 A. It accepts Class CF and FCF/TCF series fuses measuring 1-7/8 in long by 3/4 in wide by 1 in deep. The finger-safe box-lug terminals take 18 to 8 AWG conductors and the fiberglass-reinforced thermoplastic body mounts on standard DIN rail.
Panel Builders Needing Compact Single-Pole
This block suits panel builders who need a UL Listed, CSA Certified Class J fuse holder with a small 2.3 in by 0.75 in footprint. It is not for applications requiring multi-pole ganged units, indicator windows, or fuse sizes outside the 0-30 A range. Installers needing screw-mount bases or larger wire ranges should look at other series.
18 to 8 AWG Box-Lug Terminal Range
The wire-range specification decides fit: only solid or stranded conductors between 18 and 8 AWG can be terminated in the box lugs. Verify your conductor size before ordering, as larger or smaller gauges will not secure properly in this block.
Highlights
- Finger-safe design protects against accidental contact
- Accepts 18 to 8 AWG wire for versatile connections
- DIN rail mounting enables quick panel installation
- UL Listed and CSA Certified for code compliance
- Rated 600V AC and 300V DC for industrial circuits
Specifications
| Brand | EATON BUSSMANN |
|---|
Questions about this item
How much heat does the 600V AC rated block generate when carrying a 30 A load all day?
The fibre-reinforced thermoplastic body and box-lug connectors are rated for 30 A continuous duty at 600 V AC, so normal operation stays within UL temperature-rise limits for industrial fuse blocks.
What wire gauges and fuse series must I already have to install this single-pole unit?
You need 18 to 8 AWG copper wire and a Class J fuse from the FCF or TCF series, 1-7/8 in long, 0 to 30 A.
Will the finger-safe box lugs accept the same 18 to 8 AWG wire used on my older Class J clips?
Yes, the box-lug connector accommodates 18 to 8 AWG conductors, matching the wire range of many legacy Class J fuse blocks.