Bussmann
Bussmann PON60 Midget Fuse Time-Delay 60A 250V AC Non-Indicating
Time-delay midget fuse rated 60 A at 250 V AC with 10 kA interrupt capacity and 76.2 mm cylindrical fiberglass body
- Time-delay protection handles motor-start surges with 60 A rating
- 10 kA interrupt rating at 250 V AC clears faults safely
- Cylindrical 76.2 mm x 20.6 mm fiberglass body fits midget fuse holders
- Dual-element design provides overload and short-circuit response
- CE and CSA C22.2 No. 59.1 certified for code compliance
60 A Time-Delay Midget Fuse
The EATON BUSSMANN PON60 is a cylindrical, non-indicating fuse rated at 60 A and 250 V AC with a 10 kA interrupt rating. It suits industrial control panels, motor circuits and generator supplies that need a time-delay characteristic to ride through inrush currents.
Fits Standard Midget Clips
The 76.2 mm by 20.6 mm fiberglass body slides into common midget fuse blocks without tools. The non-rejection design means it will seat in any clip that accepts the PON or OTN series, so polarity or keying errors are not a concern during replacement.
250 V AC Limit and Non-Indicating Body
The fuse is certified to CSA C 22.2 No. 59.1 and CE for 250 V AC maximum; it must not be applied on higher voltage or DC systems. Because the body does not show a visual open-circuit flag, technicians must test electrically to confirm a blown element.
Highlights
- Time-delay protection handles motor-start surges with 60 A rating
- 10 kA interrupt rating at 250 V AC clears faults safely
- Cylindrical 76.2 mm x 20.6 mm fiberglass body fits midget fuse holders
- Dual-element design provides overload and short-circuit response
- CE and CSA C22.2 No. 59.1 certified for code compliance
Specifications
| Brand | EATON BUSSMANN |
|---|
Questions about this item
How can I verify the fuse is working after installation?
A continuity test across the 20.6 mm diameter cylindrical body with a multimeter will confirm the element is intact; the 10 kA interrupt rating at 250 V AC is only proven under fault conditions.
What comes in the box and what must I source separately?
The package contains the single PON60 fuse with its 76.2 mm long fiberglass body; you must provide a compatible midget fuse holder or block rated for 60 A at 250 V AC.
Which version should I choose for my application?
Select the PON60 when you need a 60 A, 250 V AC time-delay, non-indicating fuse with a 10 kA interrupt rating and the standard 76.2 mm x 20.6 mm cylindrical dimensions.