Bussmann
Bussmann DFJ-20 Class J Fast-Acting Fuse 20A 600V AC
A Class J fast-acting fuse rated 20 A at 600 V AC with a 200 kA interrupt rating
- Fast-acting protection clears faults quickly
- 200 kA interrupt rating at 600 V AC handles high fault currents
- 100 kA interrupt rating at 450 V DC suits DC circuits
- Class J design fits CH30J, JM600, JP600, JT600, JTN600 blocks
- 20 A 600 V AC rating meets standard industrial requirements
Bussmann DFJ-20 Class J Fast-Acting Fuse
The Bussmann DFJ-20 is a Class J fast-acting fuse rated for 20A at 600V AC and 450V DC. It provides overcurrent protection for industrial control panels, motor circuits and power distribution equipment. The cylindrical melamine body measures 2-1/4 in length by 13/16 in diameter. It carries an interrupt rating of 200kA at 600V AC and 100kA at 450V DC.
Installation fits CH30J, JM600, JP600.
The fuse slides into compatible non-rejection style fuse blocks without tools. Because it is non-indicating, there is no visual flag to show when the element has opened. A common issue is selecting a time-delay fuse instead of this fast-acting type, which can cause nuisance trips on inrush currents or fail to protect sensitive components quickly enough.
Verify voltage, amperage
Confirm the circuit operates at or below 600V AC or 450V DC and requires a 20A fast-acting Class J fuse. Check that the existing fuse block is a non-rejection style from the CH30J, JM600, JP600, JT600 or JTN600 series. This fuse will not fit rejection-style Class J blocks and is not suitable for circuits needing time-delay characteristics.
Highlights
- Fast-acting protection clears faults quickly
- 200 kA interrupt rating at 600 V AC handles high fault currents
- 100 kA interrupt rating at 450 V DC suits DC circuits
- Class J design fits CH30J, JM600, JP600, JT600, JTN600 blocks
- 20 A 600 V AC rating meets standard industrial requirements
Specifications
| Brand | EATON BUSSMANN |
|---|
Questions about this item
How can I confirm the DFJ-20 fuse is operating correctly after installation?
Measure voltage across the fuse with a multimeter while the circuit is live; a reading near zero volts shows the element is intact and conducting the 20 A load.
What comes with the DFJ-20 fuse and what must I source separately?
The package contains the single 20 A cylindrical fuse; a compatible Class J fuse block such as the CH30J or JM600 series must be purchased separately.
Which version of the DFJ-20 fuse should I select for a 600 V AC panel with a 200 kA fault rating?
Choose the standard DFJ-20 rated 20 A at 600 V AC with a 200 kA interrupt rating; it matches the panel requirements directly.