Bussmann
Bussmann CCP2-2-30CF Disconnect Switch 30A 600V 2-Pole
Two-pole disconnect switch rated 30 A at 600 V AC for Class J fuses, finger-safe DIN-rail mount with box-lug terminals accepting 18 to 4 AWG wire
- Finger-safe design protects against accidental contact
- 30 A 600 V rating handles demanding circuits
- DIN-rail mounting enables quick panel installation
- Box-lug terminals accept 18 to 4 AWG wire
- UL listed CE CSA cULus IEC RoHS certified
Compact 2-pole disconnect for Class J fuses
The Bussmann CCP2-2-30CF is a DIN-rail mounted fuse block rated for 600 V AC and currents up to 30 A. It accepts UL Class J fuses in the TCF series and provides finger-safe box-lug terminals for wires from 18 to 4 AWG. Electrical contractors and panel builders use it to isolate single-phase or two-wire DC loads in industrial control cabinets and generator hook-ups.
600 V AC ceiling and 30 A continuous limit
The switch is certified to CE, CSA, cULus, IEC, RoHS and UL Listed standards, but its voltage rating stops at 600 V AC and its current range tops out at 30 A. It cannot be applied on higher-voltage distribution buses or on circuits that exceed the 30 A fuse rating, so specifiers must verify system voltage and load current before selecting this block.
Replaces open knife-blade holders
This unit upgrades legacy fuse clips that lack finger-safe housings or rejection features, reducing accidental contact and preventing wrong-class fuse insertion. The jump is worthwhile when a project demands DIN-rail density, touch-safe terminals and Class J rejection in a 3-inch high footprint; it is not suited for applications needing more than two poles or ampacities above 30 A.
Highlights
- Finger-safe design protects against accidental contact
- 30 A 600 V rating handles demanding circuits
- DIN-rail mounting enables quick panel installation
- Box-lug terminals accept 18 to 4 AWG wire
- UL listed CE CSA cULus IEC RoHS certified
Specifications
| Brand | EATON BUSSMANN |
|---|
Questions about this item
Should I choose the 30 A version or a lower-amp version for my circuit?
The CCP2-2-30CF covers 0 to 30 A, so select a fuse rated at or below the circuit's full-load current without exceeding 30 A.
What does the 600 V rating mean when the switch is installed in a panel?
It certifies the disconnect for circuits up to 600 V AC, ensuring safe isolation at that voltage level.
Which fuse standard does the Class J block accept and what wire range does the box-lug connector allow?
It accepts UL Class J fuses in the TCF series and terminates wires from 18 to 4 AWG.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.



