Bussmann CBP-30BA 30 A Automotive Circuit Breaker
A 30 A plug-in circuit breaker with automatic reset, rated for 14 V DC and a 1.5 kA interrupt capacity
- Protects 30 A circuits with automatic reset
- Handles 14 V DC systems up to 1.5 kA interrupt
- Plug-in mount fits #10-32 stud terminals
- Thermoplastic housing meets RoHS compliance
- Compact 2 in depth suits truck installations
Automotive Circuit Breaker 30 A
The Bussmann CBP-30BA is a heavy-duty circuit breaker rated at 30 amps for 14V DC systems. It uses an automatic reset function and mounts via a plug-in, surface-style connection with a #10-32 stud terminal. The thermoplastic housing measures 2 inches deep, 1 3/8 inches high and 1 5/16 inches wide. It carries a 1.5 kA interrupt rating at 14V DC and meets RoHS compliance standards.
Suits Truck Electrical Protection
This breaker suits truck circuits requiring 30 A overcurrent protection with automatic reset capability. It is designed for ring terminal connections on 14V DC systems. Buyers needing a different current rating, a manual reset type, or a voltage rating above 14V DC should look at alternative devices. The plug-in mount style also requires a compatible panel or block.
Build Integration Requirements
The unit fits a standard plug-in socket and connects via a #10-32 stud for ring terminals, freeing the installer from soldering or crimping directly to the breaker body. Automatic reset restores the circuit without user intervention after a fault clears. The 1.5 kA interrupt rating handles prospective short-circuit currents on supported truck circuits. RoHS compliance simplifies regulatory approval for the final assembly.
Highlights
- Protects 30 A circuits with automatic reset
- Handles 14 V DC systems up to 1.5 kA interrupt
- Plug-in mount fits #10-32 stud terminals
- Thermoplastic housing meets RoHS compliance
- Compact 2 in depth suits truck installations
Specifications
| Brand | EATON BUSSMANN |
|---|
Questions about this item
What stud size does the CBP-30BA use for the power connection?
The breaker uses a #10-32 stud terminal for the ring-terminal power lead.
Will the automatic-reset behaviour interfere with a legacy fuse panel that expects a manual reset?
This unit resets automatically after a trip, so it will not stay open like a manual fuse; the panel must tolerate momentary interruption.
How can I confirm the 30 A rating is holding after installation?
Apply a known load up to 30 A at 14 V DC and verify the breaker remains closed without tripping.