We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Bussmann

Bussmann 16325-2 Power Distribution Block 2 Pole 350 A 600 V

SKU CH-C6CE-2B3ED

Two-pole open distribution block rated 350 A at 600 V, accepting 14 AWG to 2/0 AWG line and 14 AWG to 4 AWG load copper conductors

  • Engine BrandEATON BUSSMANN
  • Two-pole block distributes up to 350 A at 600 V
  • Accepts line conductors from 14 AWG to 2/0 AWG copper
  • Six load terminals per pole handle 14 AWG to 4 AWG copper
  • Compact footprint measures 6.5 in long by 3.75 in deep
  • Open design suits industrial panels and generator hook-ups

Two-Pole Power Distribution Block

The Bussmann 16325-2 is a two-pole power distribution block rated for 350 A and 600 V AC/DC. It accepts copper or aluminum conductors and is designed for industrial power supply applications requiring a compact, open-style block.

Conductor Range and Voltage Limits

Each pole provides two line connections for copper wire from 14 AWG up to 2/0 AWG and six load connections for copper wire from 14 AWG up to 4 AWG. The block is rated for a maximum of 600 V AC/DC and 350 A with copper conductors, defining the practical limits for safe operation.

Open-Style Mounting and Wiring Access

The open design measures 6.5 in overall length and 3.75 in overall depth, giving clear access to all termination points for straightforward installation. Installers must verify conductor sizes stay within the stated AWG ranges and ensure proper torque on each connection to avoid overheating.

Highlights

  • Two-pole block distributes up to 350 A at 600 V
  • Accepts line conductors from 14 AWG to 2/0 AWG copper
  • Six load terminals per pole handle 14 AWG to 4 AWG copper
  • Compact footprint measures 6.5 in long by 3.75 in deep
  • Open design suits industrial panels and generator hook-ups

Specifications

Engine BrandEATON BUSSMANN

Questions about this item

How do I choose between the 2-pole 350 A version and other capacities?

This model is a single 2-pole block rated for 350 A with copper conductors at 600 V AC/DC; other pole counts or ampacities would be different part numbers.

What does the 350 A rating mean once the block is installed in a panel?

It indicates the maximum continuous current each pole can carry using copper wire up to 2/0 AWG on the line side and 4 AWG on the load side without exceeding temperature limits.

How does the 600 V AC/DC rating cap what I can connect?

The 600 V rating limits the block to circuits where the nominal voltage does not exceed 600 V AC or DC, regardless of the 350 A current capacity.