Beacon Morris STC14355-05 hvac control copper 5 ft
A 5 ft copper hydronic baseboard heater element rated for 194 psi maximum pressure and fluid temperatures up to 300 °F
- ColorCopper, Silver
- Copper tubing resists corrosion for long service life
- 5 ft length fits standard hydronic baseboard installations
- 194 psi maximum pressure rating handles demanding hydronic systems
- Up to 2,160 BtuH per linear foot at 200 °F water temperature
- Compatible with TP14-05 and TP20-05 heater models
Product identity and intended use
The Beacon Morris STC14355-05 is a five-foot copper hydronic baseboard heater element designed for steam and hot-water heating systems. It suits installers and facility managers who need a replacement element rated for 194 psi maximum pressure and fluid temperatures up to 300 degrees Fahrenheit.
Build quality and connection implications
Copper tubing with a silver finish provides corrosion resistance and reliable heat transfer across the 5 ft length. The 1 1/4 inch connection size matches TP14-05 and TP20-05 enclosures, so the element slides into compatible cabinets without adapter fittings.
Practical limits of the steam and hydronic interface
At 2 psi steam the element delivers 2,130 BtuH and 2,510 BtuH; at 180 degree water it yields 1,470 and 1,730 BtuH per linear foot, rising to 1,830 and 2,160 BtuH at 200 degree water. Systems requiring higher pressures, temperatures beyond 300 degrees Fahrenheit, or different connection diameters cannot use this element.
Highlights
- Copper tubing resists corrosion for long service life
- 5 ft length fits standard hydronic baseboard installations
- 194 psi maximum pressure rating handles demanding hydronic systems
- Up to 2,160 BtuH per linear foot at 200 °F water temperature
- Compatible with TP14-05 and TP20-05 heater models
Specifications
| Brand | BEACON MORRIS |
|---|---|
| Color | Copper, Silver |
Questions about this item
What does the 194 psi maximum pressure rating mean for this hydronic element?
It sets the highest safe operating pressure for the copper tube; the system must never exceed 194 psi during testing or normal use.
What physical space is needed to mount the 5 ft copper heater element?
Allow at least 5 ft in length, 3 5/8 in height and 4 1/4 in depth, plus clearance for the 1 1/4 in connection fittings.
How is the STC14355-05 element installed and what step is often missed?
Connect the 1 1/4 in copper tube to compatible TP14-05 or TP20-05 baseboard using proper fittings; the step often missed is pressure-testing to 194 psi before filling the system.