Beacon Morris
Beacon Morris ST1443-03 Hydronic Baseboard Heater Element Steel 3 ft
A 3 ft steel hydronic baseboard heater element rated for 660 psi maximum pressure and 650 °F fluid temperature
- ColorSilver
- 3 ft steel element fits standard baseboard runs
- 1 080 BtuH per foot at 180 °F water
- 1 350 BtuH per foot at 200 °F water
- 660 psi maximum pressure rating
- 1 ¼ in connection matches TP14-03 and TP20-03 enclosures
Hydronic Baseboard Heater Element
The Beacon Morris ST1443-03 is a steel hydronic baseboard heater element designed for hydronic heating systems. It measures three feet in length and connects with a one-and-a-quarter-inch steel tube. The unit is compatible with TP14-03 and TP20-03 products for integrated installations.
Sustained Heat Output
At a water temperature of one-hundred-eighty degrees Fahrenheit the element delivers up to one-thousand-eighty BtuH per linear foot and one-thousand-six-hundred-forty BtuH per linear foot at higher flow. Raising the water temperature to two-hundred degrees Fahrenheit increases output to one-thousand-three-hundred-fifty and two-thousand-forty BtuH per linear foot respectively. The maximum fluid temperature rating is six-hundred-fifty degrees Fahrenheit.
Pressure and Steam Limits
The element withstands a maximum pressure of six-hundred-sixty psi for hydronic applications. For steam systems it is rated at six-hundred BtuH at two psi and two-thousand-two-hundred-fifty BtuH at higher steam pressure. These ratings define the practical operating envelope for the steel tubing and connection size.
Highlights
- 3 ft steel element fits standard baseboard runs
- 1 080 BtuH per foot at 180 °F water
- 1 350 BtuH per foot at 200 °F water
- 660 psi maximum pressure rating
- 1 ¼ in connection matches TP14-03 and TP20-03 enclosures
Specifications
| Brand | BEACON MORRIS |
|---|---|
| Color | Silver |
Questions about this item
How much heat does the 3 ft steel element put out when the water runs at 180 F all day?
At 180 F water temperature the element delivers up to 1,080 BtuH per linear foot, or 1,640 BtuH per linear foot depending on the rating used.
What fittings must already be in place for the 1 1/4 in connection size to work?
The element uses a 1 1/4 in tube size and connection size, so matching supply and return piping with 1 1/4 in fittings is required.
Will the TP14-03 and TP20-03 enclosures I already have accept this 3 ft steel element?
Yes, the element is listed as compatible with product types TP14-03 and TP20-03.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.