3M
3M QI-5/16-220 Cold Shrink Tube 0.65 in ID
Medium-wall EPDM rubber tube insulates 8 AWG to 2/0 AWG wire, shrinking from 0.65 in to 0.2 in ID over a 2.75 in length with 365 V dielectric strength
- Medium-wall EPDM rubber resists acids and alkalis
- Cold-shrink design installs without heat tools
- Fits 8 AWG to 2/0 AWG wire sizes
- Operates from -40 °F to 194 °F
- 365 V dielectric strength insulates reliably
Cold Shrink Tube for 8 AWG to 2/0 AWG
The 3M QI-5/16-220 is a medium-wall cold shrink tube made from EPDM rubber. It is designed for electricians who need to insulate or splice cables without using a heat gun. The tube arrives pre-expanded on a removable core and contracts when the core is pulled. It suits maintenance and field repairs where open flame or hot tools are impractical.
0.65 in ID Fits 8 AWG to 2/0 AWG
The critical specification is the expanded inner diameter of 0.65 in, which shrinks down to 0.2 in after core removal. This range covers wire sizes from 8 AWG up to 2/0 AWG. Selecting the correct tube depends on matching this diameter to the cable or connector being insulated. An incorrect diameter will prevent a reliable seal.
Withstands -40 to 194 Degrees F Continuously
The EPDM rubber operates across a temperature range of -40 to 194 degrees F. It resists acids and alkalis during prolonged exposure. The material carries a dielectric strength of 365 V and is not flame retardant. These properties mean the insulation remains stable under sustained thermal and chemical stress rather than only during brief peaks.
Highlights
- Medium-wall EPDM rubber resists acids and alkalis
- Cold-shrink design installs without heat tools
- Fits 8 AWG to 2/0 AWG wire sizes
- Operates from -40 °F to 194 °F
- 365 V dielectric strength insulates reliably
Specifications
| Brand | 3M |
|---|
Questions about this item
What does the 0.65 in inside diameter mean when the tube is on a cable?
The tube ships at 0.65 in ID and shrinks down to 0.2 in, so it will grip cables from 8 AWG up to 2/0 AWG once the core is removed.
How does the 365 V dielectric strength limit what the tube can insulate?
The 365 V rating means the EPDM rubber wall is tested for low-voltage work only; do not use it on circuits that exceed that level.
What spacing does the 2.75 in length need on a splice?
Each piece covers 2.75 in, so plan at least that much straight cable for the tube to sit flat after shrinking.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.