Vertiv
Vertiv VP5N60A3 server accessory 60A 208V Delta 17.2kW 24 C13 12 C19 10ft 3P+E IP67
Distributes 17.2 kW of three-phase 208 V power to 24 locking C13 and 12 locking C19 outlets with individual switching and a 10 ft IP67 plug
- TypeUnit Level Monitoring
- SpecificationsVoltage: 200-240V Delta Current: 60A x 3 Phase DELTA VA per
- Unit-level monitoring gives real-time power visibility
- 60 A three-phase Delta feed delivers 17.2 kW at 208 V
- 24 locking C13 plus 12 locking C19 outlets secure dense deployments
- 10 ft cord with IEC 60309 3P+E IP67 plug resists water ingress
- Six 20 A double-pole magnetic breakers provide 5 kAIC branch protection
Three-phase delta PDU
The Vertiv VP5N60A3 is a switched rack PDU rated for 60 A three-phase delta at 200-240 V. It delivers 17.2 kW at 208 V through 36 locking outlets fed by a 10 ft cord with an IEC 60309 3P+E IP67 plug.
Suits high-density racks needing per-outlet control
Data-centre operators who want unit-level monitoring and individual outlet switching across three-phase delta service will use the LCD touchscreen and 36 LEDs. Sites limited to single-phase feeds or lower amperage panels cannot connect this unit.
60 A three-phase delta input
The 60 A 3P+E IP67 inlet and six 20 A double-pole breakers define the power architecture. Verify that your facility provides 200-240 V delta at 60 A per phase before ordering.
Highlights
- Unit-level monitoring gives real-time power visibility
- 60 A three-phase Delta feed delivers 17.2 kW at 208 V
- 24 locking C13 plus 12 locking C19 outlets secure dense deployments
- 10 ft cord with IEC 60309 3P+E IP67 plug resists water ingress
- Six 20 A double-pole magnetic breakers provide 5 kAIC branch protection
Specifications
| Brand | Vertiv |
|---|---|
| Model | VP5N60A3 |
| Type | Unit Level Monitoring |
| Specifications | Voltage: 200-240V Delta Current: 60A x 3 Phase DELTA VA per Input (Load Capacity): 17.2kW (208V) Frequency: 50/60Hz Over Current Protection: (6) 20A Double Pole Magnetic Breakers (5kAIC Rated) Switch: Breaker/Switch Combination LCD Touchscreen Display / Auto Oriented: Yes Indicators - LED(s): 36 Power Cable Wire Gauge: 6/4 Power Cable Length: 10ft / 3m Power Entry Location: Bottom Front Plug Type: IEC60309 3P + E, 60A, Watertight IP67 Combined Total Receptacle/Socket Quantity: 36 Alternating Phase/Circuits: Yes Receptacle/Socket Type #1: U-Lock IEC C13 - Quantity on Face: 24 - Quanti |
| Shipping weight | 11.34 kg |
| Package size | 1689 × 102 × 76 mm |
Questions about this item
How much heat and noise does the 60A three-phase Delta unit produce when running at 17.2kW all day?
The rPDU has no built-in fans; heat output equals the connected load and noise is limited to the six 20A magnetic breakers clicking under fault conditions.
What inlet plug must my facility provide for the 10ft cord with IEC60309 3P+E IP67 connector?
A 60A 200-240V Delta three-phase plus earth outlet matching IEC60309 60309 3P+E watertight IP67 is required.
Can I plug older C13 and C19 server cords into the 24 C13 and 12 C19 U-Lock outlets without adapters?
Yes — standard IEC C13 and C19 plugs fit the U-Lock receptacles; the locking tabs engage automatically and release with a thumb press.
New to this? Buying server hardware with crypto — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these