Vertiv
Vertiv PSI5-5000RT208 UPS 5000VA 4250VA 3825W 208V 2U Rack/Tower
Line-interactive UPS delivers 4250 VA and 3825 W from a 2U rack or tower chassis with four NEMA L6-30R outlets and a four-hour recharge
- International Version208V
- Input Voltage Range150-281VAC
- Input Frequency55~65Hz (57~63Hz Battery to Normal comeback)
- Input ConnectionNEMA L6-30P
- VA Rating4250VA
- Watts3825W
Option PSI5-5000RT208
- 0 minutes runtime at full load protects critical equipment
- 0 minutes runtime at half load extends availability
- 4 hour recharge to 90% restores backup quickly
- 2U rack/tower form factor fits dense installations
- 2064 joules surge energy rating shields connected devices
What this UPS delivers
The Vertiv PSI5-5000RT208 is a line-interactive UPS rated at 5000 VA and 3825 W with a 208 V AC input and output. It fits a 2U rack or tower footprint and provides four NEMA L6-30R outlets for connected equipment. The unit is suited for server rooms and network closets that require battery backup with hot-swappable modules and an LCD status display.
Installation checks
Verify that your facility supplies 208 V AC through a NEMA L6-30P plug and that the input voltage stays within the 150-281 VAC range. Confirm the rack or tower space can accommodate a 2U high unit measuring 3.5 by 17.2 by 24.8 inches and weighing 87.7 lbs. Ensure the operating environment remains between 32 and 104 °F with humidity from 20 to 90 percent non-condensing.
Sustained-load behaviour
At full load the battery provides 3.0 minutes of run time, extending to 10.0 minutes at half load. After a discharge the internal VRLA batteries recharge to 90 percent capacity in four hours. Surge protection is rated at 2064 joules and the unit carries UL 1778 and c-UL-us listings for continuous operation.
Highlights
- 0 minutes runtime at full load protects critical equipment
- 0 minutes runtime at half load extends availability
- 4 hour recharge to 90% restores backup quickly
- 2U rack/tower form factor fits dense installations
- 2064 joules surge energy rating shields connected devices
Specifications
| Brand | Liebert |
|---|---|
| Series | PSI5 |
| Model | PSI5-5000RT208 |
| International Version | 208V |
| Input Voltage Range | 150-281VAC |
| Input Frequency | 55~65Hz (57~63Hz Battery to Normal comeback) |
| Input Connection | NEMA L6-30P |
| VA Rating | 4250VA |
| Watts | 3825W |
| Output Voltage | 208VAC (100/110/115/125 VAC TDU Required) |
| Outlets | 4 |
| Outlet Type | 3 x NEMA L6-30R, 1 x NEMA L6-30R |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Battery Run Time | Full Load: 3.0 min Half Load: 10.0 min |
| Battery Recharge Time | 4 hours to recover 90% |
| Battery Replaceable | PSI5-72VBATT |
| Approvals | UL 1778, c-UL-us Listed |
| Rackmountable | 2U Rack/Tower |
| Surge Energy Rating | 2064 Joules |
| Temperature | Operating Temperature: 32°-104°F (0°-40°C) Storage Temperature: 5°-120°F (-15° - 50°C) |
| Humidity | 20% to 90% non-condensing |
| Dimensions | 3.5" x 17.2" x 24.8" |
| Weight | 87.7 lbs. |
| Shipping weight | 44.82 kg |
| Package size | 678 × 551 × 259 mm |
Other versions of this model
5 more in the same range
Same family, different memory, cooler or clock — compare before you commit.
Vertiv PSI5-1500RM1201U UPS 1440VA 1350W 120V 1U
- 120V
- 75-146VAC
Vertiv PSI5-800RT120N 800VA 720W Line-Interactive UPS 2U Rack/Tower
- 120V
- 75-146VAC
Vertiv PSI5-3000RT120 UPS 2880VA 2700W 120V 2U Rack/Tower
- 120V
- 75-146VAC
Questions about this item
What comes in the box with the PSI5-5000RT208 and what must be purchased separately for 120V equipment?
The unit ships with a 2U rack/tower chassis, internal VRLA batteries, an LCD status display, an RJ-45 network port and four NEMA L6-30R outlets. A step-down transformer is required to power 100, 110, 115 or 125 VAC loads.
Which battery module is the correct replacement for this UPS?
The hot-swappable replacement cartridge is the PSI5-72VBATT, designed for tool-less exchange while the UPS remains online.
How long will the UPS sustain my 3825 W load during a mains failure?
At the full 3825 W rating the internal batteries provide 3.0 minutes of runtime; at half load the runtime extends to 10.0 minutes.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Innovation First, Inc. 1UCMA-137 1U Cable Management Arm 19" 28.5"-33" computer accessory
- Product Type:Cable…
- Panel Width:19" Rac…
Vertiv 4UTELECOMRKIT 19 in rack mount bracket accessory
- GXT4U Wall Mount Br…
- Mounting Bracket