Vertiv
Vertiv PSI5-1500MT120 1440VA 1350W Mini Tower UPS
Line-interactive UPS delivers 1350 W pure sine-wave output, automatic voltage regulation from 83 to 159 VAC, and six NEMA 5-15R outlets in a mini-tower form factor
- International Version120V
- Input Voltage Range75-146VAC
- Input Frequency55-65 Hz (57-63 Hz Battery to Normal comeback)
- Input ConnectionNEMA 5-15P
- VA Rating1440 VA
- Watts1350W
Option PSI5-1500MT120
- Line-interactive design delivers pure sine wave output for sensitive IT loads
- Automatic Voltage Regulation corrects 83-159 VAC input without draining the battery
- Six NEMA 5-15R outlets provide 1440 VA / 1350 W of battery-backed power
- Surge protection rated to ANSI C62.41 Category A Level 3 with 1372 J energy absorption
- Optional Unity card enables remote monitoring of up to 50 UPS units via Trellis Power Insight
1440VA Mini Tower UPS
The Vertiv PSI5-1500MT120 is a line-interactive uninterruptible power supply rated at 1440VA and 1350W for 120VAC environments. It protects workstations, network closets and small server rooms from outages, brownouts and noise interference.
Thermals, noise and power draw
The unit operates between 0 and 40 degrees Celsius with 20 to 90 percent non-condensing humidity. Automatic Voltage Regulation corrects input from 83 to 159VAC without engaging the battery, reducing heat and acoustic output during normal voltage fluctuations.
Six NEMA 5-15R outlets and Unity card slot
Six rear outlets distribute battery-backed and surge-protected power to connected loads. An optional Vertiv Liebert Unity communication card enables remote monitoring of up to 50 UPS units through the free Vertiv Trellis Power Insight application.
Highlights
- Line-interactive design delivers pure sine wave output for sensitive IT loads
- Automatic Voltage Regulation corrects 83-159 VAC input without draining the battery
- Six NEMA 5-15R outlets provide 1440 VA / 1350 W of battery-backed power
- Surge protection rated to ANSI C62.41 Category A Level 3 with 1372 J energy absorption
- Optional Unity card enables remote monitoring of up to 50 UPS units via Trellis Power Insight
Specifications
| Brand | Liebert |
|---|---|
| Series | PSI5 |
| Model | PSI5-1500MT120 |
| International Version | 120V |
| Input Voltage Range | 75-146VAC |
| Input Frequency | 55-65 Hz (57-63 Hz Battery to Normal comeback) |
| Input Connection | NEMA 5-15P |
| VA Rating | 1440 VA |
| Watts | 1350W |
| Output Voltage | 120VAC (100/110/115/125VAC user-configurable) |
| Outlets | 6 |
| Outlet Type | 6 x NEMA 5-15R |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Battery Recharge Time | 6-8 hours to recover 90% |
| Approvals | UL 1778, c-UL-us Listed |
| Rackmountable | Mini Tower |
| Surge Protection | ANSI C62.41, Category A, Level 3 1372 J |
| Protection | Electronic (over current, short circuit w/ latching shutdown) |
| Temperature | Operating Temperature, ° F (° C) 32-104 (0-40) Storage Temperature °F (°C)-5- 122 (-15- 50) |
| Humidity | 20% to 90% non-condensing |
| Dimensions | 5.7" x 19.1" x 8.7" |
| Weight | 40.1 lbs. |
| Shipping weight | 22.18 kg |
| Package size | 584 × 356 × 254 mm |
Other versions of this model
5 more in the same range
Same family, different memory, cooler or clock — compare before you commit.
Vertiv PSI5-1100RT120 UPS 1100VA 990W 120V 2U Rack/Tower
- 120V
- 75-146VAC
Questions about this item
How do I install the PSI5-1500MT120 and which connection step is often missed?
Plug the NEMA 5-15P input into a grounded 120 VAC wall outlet, then connect equipment to the six NEMA 5-15R outlets. The step often missed is configuring the output voltage to 100, 110, 115, 120 or 125 VAC to match your devices before powering on.
What maintenance will the PSI5-1500MT120 need and when should the battery be replaced?
The valve-regulated lead-acid battery typically lasts three to five years; replace it when runtime drops noticeably. Recharge takes six to eight hours to reach ninety percent after a full discharge. Keep the unit in 0 to 40 °C ambient temperature and twenty to ninety percent non-condensing humidity for maximum life.
What is the first limit the PSI5-1500MT120 hits under sustained heavy load?
The 1350 W output rating is the first hard limit; exceeding it triggers electronic over-current protection with latching shutdown. If the load stays within 1350 W, battery runtime becomes the next constraint, and prolonged operation at 40 °C may reduce component longevity.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Innovation First, Inc. 1UCMA-137 1U Cable Management Arm 19" 28.5"-33" computer accessory
- Product Type:Cable…
- Panel Width:19" Rac…
Vertiv 4UTELECOMRKIT 19 in rack mount bracket accessory
- GXT4U Wall Mount Br…
- Mounting Bracket