Tripp Lite
Tripp Lite SU2000RTXLCD2U UPS 2000VA 1800W
Double-conversion UPS delivers 2000VA 1800W pure sine-wave power with zero transfer time, six switched NEMA 5-15/20R outlets plus one unswitched L5-20R, and hot-swappable batteries
- Battery TypeValve Regulated Lead Acid (VRLA)
- Double-conversion online topology delivers zero transfer time and pure sine wave output
- 1800 W capacity with 0.9 power factor supports dense rack loads
- Two switchable load banks enable remote reboot and load shedding
- 570 joules surge suppression shields connected gear from transients
- Field-replaceable hot-swap batteries extend runtime without downtime
Double-Conversion Online UPS
The Tripp Lite SU2000RTXLCD2U is a 2000VA / 1800W double-conversion UPS that delivers pure sine wave output with ±2% voltage regulation. It operates from 100/110/120/127V inputs at 50/60 Hz and provides zero transfer time to battery mode for critical network and data center equipment.
Upgrade from Line-Interactive or Standby Units
Moving from a line-interactive or standby UPS is worth it when connected hardware cannot tolerate any transfer delay or voltage distortion. The 0.9 power factor and 570 joules of surge suppression support dense rack loads that exceed the capacity of basic battery backups.
Hardwired Input and Fixed Outlet Configuration
The unit requires a compatible NEMA L5-20P input connection and provides one unswitched NEMA L5-20R outlet plus two switched banks of three NEMA 5-15/20R outlets each. Installations without the matching plug type or rack space for a 2U form factor cannot use this UPS.
Highlights
- Double-conversion online topology delivers zero transfer time and pure sine wave output
- 1800 W capacity with 0.9 power factor supports dense rack loads
- Two switchable load banks enable remote reboot and load shedding
- 570 joules surge suppression shields connected gear from transients
- Field-replaceable hot-swap batteries extend runtime without downtime
Specifications
| Brand | TRIPP LITE |
|---|---|
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Shipping weight | 28.58 kg |
| Package size | 600 × 510 × 236 mm |
Questions about this item
What rack height and outlet types does the SU2000RTXLCD2U require?
The 2U rackmount unit provides six NEMA 5-15/20R outlets in two switchable banks plus one unswitched NEMA L5-20R outlet.
How do you connect the UPS for double-conversion operation, and what setting is often missed?
Wire the input to a 100/110/120/127V 50/60 Hz source, then enable on-line double-conversion mode in the LCD menu to achieve zero transfer time.
When and how should the internal VRLA batteries be replaced?
Batteries are field-replaceable and hot-swappable; replace them when the LCD shows a battery-warning icon or runtime drops below your required level.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
YOUHUA SATA Cable Kit 2×Data 0.48 m 2×Power 0.16 m
- Sata cables: 2 SATA…
Micro Connectors SATA cable 40 inches straight to right angle locking latch black 3 pack
- Black