TeKit
TeKit C20 to 2×C19 Y Splitter 12AWG 3.3ft
A C20 to dual C19 Y splitter cable rated 20A 250V with 12AWG and 14AWG conductors, 3.3ft total length for blade server power distribution
Struck-through versions exist but are not stocked here.
- Connect two C19 devices from one C20 outlet
- 3 ft overall length with 1.6 ft split legs
- UL Listed and RoHS compliant for safety
- 12 AWG main cable rated 20 A 250 V
- 14 AWG branch cables rated 15 A 250 V
C20 to Dual C19 Y Splitter
This IEC 320 C20 to dual C19 splitter connects two blade server chassis or high-power network devices to a single C20 outlet. The 3.3 ft cord reduces cable clutter and frees space on UPS, surge protector and PDU units. UL Listed and RoHS compliant construction ensures safe power distribution for professional server environments.
Replaces Dual C20 Cords
Instead of running two separate C20 cables to a power distribution unit, this Y splitter consolidates the connection into one C20 plug. The upgrade is worth it when rack space is limited and you need to power two C19-equipped devices from one available C20 receptacle on a PDU or UPS.
20 A Headroom on Main Leg
The C20 to split section uses 12 AWG wire rated for 20 A at 250 V, while each split leg uses 14 AWG wire rated for 15 A at 250 V. It comfortably handles dual blade chassis drawing up to 15 A each, but total combined load must stay within the 20 A main-leg limit.
Highlights
- Connect two C19 devices from one C20 outlet
- 3 ft overall length with 1.6 ft split legs
- UL Listed and RoHS compliant for safety
- 12 AWG main cable rated 20 A 250 V
- 14 AWG branch cables rated 15 A 250 V
Specifications
No published specifications for this item yet.
Other versions of this model
2 more in the same range
Same family, different memory, cooler or clock — compare before you commit.
Questions about this item
How much clearance does the 1.6 ft split-to-C19 section need in a rack?
The split-to-C19 legs are 1.6 ft each, so allow at least that much vertical space from the splitter body to the device inlets.
Which connector should I plug in first to avoid bending the 12 AWG trunk?
Seat the C20 plug into the PDU or UPS outlet before routing the Y legs, so the heavier 12 AWG section takes no strain.
When should I replace the cord if the 15 A C19 legs show wear?
Inspect the 14 AWG legs regularly; replace the assembly if insulation cracks, pins discolor, or the cable feels warm near the C19 connectors.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Refrigiwear 0379 Cold Protection Gloves Large Hi-Vis Lime
- Large
- Gloves





