We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

SURGEX

SURGEX UPS-2000-OL UPS 2000 VA 120V 5 Outlets

SKU CH-B4R9-1574X MPN UPS-2000-OL

On-line 2000 VA battery backup with five outlets, LCD monitoring and runtime expandable to 18 hours using external packs

  • Input Voltage Range120 VAC (80 - 138 V at 100% load) 60-138 V at 40% load
  • Input Frequency50/60 Hz
  • Input Connection5-20P
  • VA Rating2000 VA
  • Output Voltage120V
  • Output Frequency50/60 Hz auto sensing
  • On-line technology protects equipment from all power disturbances
  • 2000 VA capacity supports demanding loads through five outlets
  • Enterprise-grade LCD gives detailed status at a glance
  • Runtime scales from 7-11 minutes to 18 hours with external battery packs
  • RS-232 or optional SNMP card enables remote management

SurgeX 2000 VA On-Line UPS

The SurgeX UPS-2000-OL is a 2000 VA on-line uninterruptible power supply designed for critical network and server hardware. It accepts a wide 60–138 V input range at reduced load and delivers regulated 120 V output with auto-sensing frequency. Five outlets include one NEMA L5-20R and four NEMA 5-20R receptacles.

Internal battery versus extended runtime

Internal batteries provide 7–11 minutes of holdover, sufficient for orderly shutdowns during brief outages. Adding external battery packs extends runtime to 18 hours, with each pack containing its own charger. Recharge typically completes in under four hours.

Enterprise racks needing scalable holdover

This unit suits rack, tower or wall-mount installations that require on-line power conditioning and long-duration backup via modular packs. It is not for buyers who need only short desktop runtime, who lack space for a 79.40 lb chassis, or who require management protocols beyond RS-232 or optional SNMP.

Highlights

  • On-line technology protects equipment from all power disturbances
  • 2000 VA capacity supports demanding loads through five outlets
  • Enterprise-grade LCD gives detailed status at a glance
  • Runtime scales from 7-11 minutes to 18 hours with external battery packs
  • RS-232 or optional SNMP card enables remote management

Specifications

BrandSURGEX
ModelUPS-2000-OL
Input Voltage Range120 VAC (80 - 138 V at 100% load) 60-138 V at 40% load
Input Frequency50/60 Hz
Input Connection5-20P
VA Rating2000 VA
Output Voltage120V
Output Frequency50/60 Hz auto sensing
Outlets5
Outlet Type1 x NEMA L5 - 20R + 4 x NEMA 5 - 20R
Battery Run Time7-11 min (internal batteries) to 18 hours using External Battery Packs (EBP)
Battery Recharge TimeTypically < 4 hours
Interface PortRS-232 or SNMP (optional card)
ApprovalsFCC, UL, cUL
FeaturesOn-line Technology
Ensures compatibility with all connected equipment.
Enterprise Grade LCD
More monitoring & precise information from the front.
Almost Infinite Scalable Runtimes
As much as 18 hours of holdover, each battery pack has its own charger.
Multi Form Factor
Tower/Rack-mounting and Wall-mounting saves space.
Multiple Communications Capability
RS232 & SNMP.
Emergency Power Off Switch (EPO)
Compliance with the highest application safety standards.
Fast Battery Recharge
Typically less than 4 hours to recharge an endless supply.
Low Noise and Less Power Consumption
"Smart Fan"
Dimensions5.20" x 17.30" x 21.70"
Weight79.40 lbs.
Shipping weight27.22 kg
Package size686 × 572 × 305 mm

Questions about this item

What clearance does the 5.20" x 17.30" x 21.70" chassis need for tower, rack or wall mounting?

The unit measures 5.20 inches high, 17.30 inches wide and 21.70 inches deep; allow extra space for the 79.40 lb weight and for cable bend radius at the rear NEMA L5-20R and four NEMA 5-20R outlets.

How is the 5-20P input cord connected and what step is often missed?

Plug the 5-20P cord into a 120 VAC branch circuit rated for 20 A, then configure the optional RS-232 or SNMP card for monitoring; the step often missed is enabling the Emergency Power Off switch wiring before first start-up.

When must the internal battery be replaced and what runtime can external packs add?

Internal batteries typically last three to five years; adding External Battery Packs extends holdover from the standard 7-11 minutes up to 18 hours, and each pack includes its own charger for fast recharge.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.