Schneider Electric
Schneider Electric M9F43106 C60BP 6A 1-pole load center
A 6 A single-pole miniature circuit breaker with D-curve thermal-magnetic trip, 14 kA interrupting rating at 120/240 V AC, and DIN-rail mounting
- Thermal magnetic trip protects branch circuits reliably
- 14 kA interrupting rating handles high fault currents
- 6 A D-curve rating suits inductive load inrush
- DIN rail mounting fits standard panel layouts
- Screw clamp terminals accept 18 to 8 AWG wire
Schneider Electric M9F43106 6A DIN-rail breaker
The Schneider Electric M9F43106 is a single-pole miniature circuit breaker rated at 6 amps with a D-curve thermal-magnetic trip. It mounts on standard DIN rail and provides branch-circuit protection for industrial control panels and machinery.
Verify rail space voltage and wire gauge
Confirm the enclosure has 18 mm of DIN-rail width available and that the system voltage does not exceed 240/415 V AC or 60 V DC. The screw-clamp terminals accept conductors from 18 AWG up to 8 AWG only.
Toggle actuator and screw-clamp terminals
The front-mounted toggle gives clear visual indication of the breaker state while the screw-clamp connections allow secure field wiring without specialised tools. No additional accessories are included in the package.
Highlights
- Thermal magnetic trip protects branch circuits reliably
- 14 kA interrupting rating handles high fault currents
- 6 A D-curve rating suits inductive load inrush
- DIN rail mounting fits standard panel layouts
- Screw clamp terminals accept 18 to 8 AWG wire
Specifications
| Brand | SCHNEIDER ELECTRIC |
|---|
Questions about this item
Does the Schneider Electric M9F43106 come with mounting hardware or DIN rail clips, or must they be purchased separately?
The breaker uses a DIN-rail mounting style and screw-clamp terminals for 18–8 AWG wire; mounting rail and clips are not included and must be sourced separately.
How do I decide between the D-curve 6 A version and other C60BP ratings for my branch-circuit application?
Choose the D-curve 6 A unit when protecting loads with high inrush currents such as transformers or motors; select a different C60BP amperage or curve only if the load profile and local code require it.
What does the 14 kA AIR rating mean when the breaker is installed in a 240 V panel?
At 120/240 V AC the breaker can safely interrupt up to 14 kA of prospective fault current, limiting let-through energy to protect downstream wiring and equipment.