Schneider Electric
Schneider Electric M9F22201 C60SP 1 A 2-pole load center
Two-pole DIN-rail supplementary protector rated 1 A with 14 kA interrupting capacity at 240 V AC, screw-clamp terminals for 18–8 AWG wire
- 1 A thermal-magnetic protection for branch circuits
- 14 kA interrupting capacity at 240 V AC
- Two-pole IEC supplementary protector, C curve
- DIN-rail screw-clamp terminals accept 18–8 AWG
- UL 1077 recognised for supplementary protection
Schneider Electric C60SP 1 A 2-pole breaker
The Schneider Electric M9F22201 is a C60SP series miniature circuit breaker rated at 1 A with two poles. It mounts on a DIN rail and uses screw-clamp terminals for wire sizes from 18 AWG to 8 AWG. The thermal-magnetic trip unit provides branch-circuit protection in single-phase installations.
Suited for supplementary protection tasks
This device suits panels requiring an IEC supplementary protector with a C-curve characteristic and a 14 kA interrupting rating at 240 V AC. It is not intended for applications that demand a UL 1077 recognised supplementary protector with a different voltage or pole count. Buyers needing a DC-rated breaker or a single-pole unit should look elsewhere.
UL 1077 recognised supplementary protector
The breaker carries UL 1077 recognition and is rated for 240/415/440 V AC. This listing determines whether it meets the code requirements for your specific supplementary protection application. Verify the standard before purchase.
Highlights
- 1 A thermal-magnetic protection for branch circuits
- 14 kA interrupting capacity at 240 V AC
- Two-pole IEC supplementary protector, C curve
- DIN-rail screw-clamp terminals accept 18–8 AWG
- UL 1077 recognised for supplementary protection
Specifications
| Brand | SCHNEIDER ELECTRIC |
|---|
Questions about this item
Will the 3.19 in length and 1.42 in width fit my DIN rail enclosure?
The breaker measures 3.19 in long, 1.42 in wide and 2.83 in deep, and it mounts on a DIN rail so the enclosure must accept that footprint and rail spacing.
How do I wire the screw-clamp terminals correctly?
Strip the conductor, insert it into the screw-clamp terminal and tighten the screw to the torque printed on the device; the terminals accept 18 AWG to 8 AWG wire.
When should the C60SP 1 A 2-pole breaker be replaced?
Replace it if it trips repeatedly without an overload, shows discolouration or damage, or after a fault current near the 14 kA interrupting rating at 240 V AC.