We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Eaton

Eaton SRP-R-C25 44U server accessory 25 kW cooling

SKU CH-WNZ0-2H1TE MPN SRP-R-C25

A 44U self-cooling modular data centre rack with a 25 kW active DX air-conditioning unit delivering 2,950 CFM airflow

  • ColorBlack
  • SpecificationsINPUT Input Connection Type: 3-wire / 4-wire + Ground Voltag
  • 8 kW cooling capacity handles dense server loads
  • 2,950 CFM airflow maintains consistent rack temperatures
  • 44U deep rack fits equipment up to 48.7 inches deep
  • 7-inch colour touchscreen gives direct control and monitoring
  • 3,000 lb stationary weight capacity supports heavy configurations

Pre-Configured 44U Modular Data Centre

The Eaton SRP-R-C25 is a self-cooling, pre-configured modular data centre housed in a 44U rack enclosure. It targets organisations that need a ready-to-deploy compute environment with integrated active cooling, removing the requirement for a separate computer room air-conditioning installation. The unit ships new and fully assembled for immediate placement.

208 V 60 Hz Three- or Four-Wire Input Constraint

Operation requires a 208 VAC supply at 60 Hz with either a three-wire or four-wire plus ground connection. Facilities without this specific voltage and phase arrangement cannot power the unit without additional electrical work. The fixed frequency compatibility also limits deployment to regions matching the 60 Hz standard.

25.8 kW Cooling Capacity with 48.7-Inch Device Depth

The direct-expansion R410A system delivers 25.8 kW (88,000 BTU) of cooling capacity and moves 2,950 CFM of air, supporting dense equipment loads up to the stationary weight limit of 3,000 lb. Maximum device depth is 48.7 in, so deeper servers or blade chassis will not fit. Operating temperature range is 18 °C to 40 °C with audible noise below 68 DBA.

Highlights

  • 8 kW cooling capacity handles dense server loads
  • 2,950 CFM airflow maintains consistent rack temperatures
  • 44U deep rack fits equipment up to 48.7 inches deep
  • 7-inch colour touchscreen gives direct control and monitoring
  • 3,000 lb stationary weight capacity supports heavy configurations

Specifications

BrandTripp Lite by Eaton
ModelSRP-R-C25
ColorBlack
SpecificationsINPUT
Input Connection Type: 3-wire / 4-wire + Ground
Voltage Compatibility (VAC): 208
Input Frequency: 60 Hz
OUTPUT
Frequency Compatibility: 60 Hz
COOLING
Airflow: 2,950 CFM
Cooling Type: Active
Cooling Capacity (BTUs): 88000
Cooling Capacity (kW): 25.8
Refrigerant: R410A
Full Cooling Specifications: Direct Expansion (DX)
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display: 7-inch color touchscreen
PHYSICAL
Color: Black
Rack Height : 44U
Rack Depth: Deep
Maximum Device Depth (in.): 48.7
Unit Dimensions (hwd / in.): 95.070 x 40.390 x 64.880
Unit Weight (lbs.): 1447
Weight Capac
Shipping weight680.39 kg
Package size2591 × 1778 × 1219 mm

Questions about this item

Should I choose the 44U rack height or a different capacity for my equipment?

This unit is a fixed 44U configuration with a maximum device depth of 48.7 inches and a stationary weight capacity of 3000 lbs, so choose it when your gear fits those dimensions.

What does the 25.8 kW cooling capacity mean once the unit is running in my data center?

It can remove up to 25.8 kW of heat (88000 BTU/h) while delivering 2950 CFM of airflow, keeping inlet temperatures within the 64° to 104°F operating range.

What does the 208 VAC, 60 Hz input cap in practice?

The 3-wire or 4-wire plus ground connection at 208 VAC and 60 Hz limits installation to North American three-phase service and sets the maximum cooling output at 25.8 kW.

New to this? Buying server hardware with crypto — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.