We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Eaton

Eaton SRP-R-C12 44U self-cooling server accessory 12 kW

SKU CH-HV5Z-4EW24 MPN SRP-R-C12

A 44U self-cooling rack delivers 12.8 kW active cooling with 1,475 CFM airflow and a 7-inch touchscreen

  • ColorBlack
  • SpecificationsINPUT Input Connection Type: 3-wire / 4-wire + Ground Voltag
  • 12 kW active cooling handles dense server loads
  • 44U deep rack fits equipment up to 48.7 in
  • 1,475 CFM airflow maintains 18–40 °C operating range
  • 7-inch colour touchscreen gives instant status and alerts
  • 3,000 lb stationary capacity supports heavy deployments

44U self-cooling rack system

The Eaton SRP-R-C12 is a pre-configured modular data centre that fits 44U of equipment in a deep rack. It targets IT teams who need a standalone, room-neutral enclosure with integrated cooling for dense server deployments. The unit operates on 208 VAC three-phase power at 60 Hz and supports a stationary load of 3000 lbs.

12.8 kW DX cooling with touchscreen control

A built-in direct-expansion air conditioner delivers 12.8 kW of cooling capacity and moves 1,475 CFM of airflow using R410A refrigerant. The active cooling module is managed through a 7-inch colour touchscreen on the front panel, giving operators direct access to temperature alerts and configuration without external software.

Handles up to 48.7-inch deep hardware in 18–40 °C

The 44U frame accepts devices up to 48.7 inches deep and weighs 1407 lbs when fully assembled. It maintains safe inlet temperatures in ambient conditions from 18 °C to 40 °C at elevations up to 4000 m. Audible noise stays below 68 DBA, making it unsuitable for office-adjacent spaces that require quieter operation.

Highlights

  • 12 kW active cooling handles dense server loads
  • 44U deep rack fits equipment up to 48.7 in
  • 1,475 CFM airflow maintains 18–40 °C operating range
  • 7-inch colour touchscreen gives instant status and alerts
  • 3,000 lb stationary capacity supports heavy deployments

Specifications

BrandTripp Lite by Eaton
ModelSRP-R-C12
ColorBlack
SpecificationsINPUT
Input Connection Type: 3-wire / 4-wire + Ground
Voltage Compatibility (VAC): 208
Input Frequency: 60 Hz
OUTPUT
Frequency Compatibility: 60 Hz
COOLING
Airflow: 1,475 CFM
Cooling Type: Active
Cooling Capacity (BTUs): 43686
Cooling Capacity (kW): 12.8
Refrigerant: R410A
Full Cooling Specifications: Direct Expansion (DX)
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display: 7-inch color touchscreen
PHYSICAL
Color: Black
Rack Height : 44U
Rack Depth: Deep
Maximum Device Depth (in.): 48.7
Unit Dimensions (hwd / in.): 95.070 x 40.390 x 64.880
Unit Weight (lbs.): 1407
Weight Capac
Shipping weight657.71 kg
Package size2591 × 1778 × 1219 mm

Questions about this item

How often does the R410A refrigerant in the 12.8 kW cooling unit need recharging or replacement?

The sealed DX cooling circuit uses R410A refrigerant and is designed for continuous operation without scheduled recharging; only a certified HVAC technician should service it if a leak develops.

At what point does the 1,475 CFM airflow become the limiting factor for the 12 kW heat load?

The 12.8 kW (43,686 BTU) cooling capacity is the rated limit; as long as the total IT heat load stays at or below 12 kW the airflow is sufficient.

What is the audible noise level when the unit runs continuously at full cooling capacity?

The manufacturer rates audible noise at less than 68 DBA during operation.

New to this? Buying server hardware with crypto — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.