We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Eaton

Eaton SRCOOL5KWRM42U 42U Self-Cooling Rack 5.5 kW 208V server accessory

SKU CH-7SAN-NW72T MPN SRCOOL5KWRM42U

A 42U deep rack enclosure with a pre-installed 5.5 kW self-contained cooling unit, 208V single-phase power and 27U of usable equipment space

  • ColorBlack
  • SpecificationsINPUT Input Phase: Single-Phase Electrical Consumption (Max)
  • Self-contained cooling removes need for separate HVAC installation
  • 5 kW capacity handles dense server loads in edge sites
  • 470 CFM airflow directs cold air through 27U usable space
  • Built-in SNMP card enables 24/7 remote monitoring and control
  • 7-inch touchscreen simplifies commissioning and diagnostics on site

Self-Cooling 42U Rack for Edge Computing

The Eaton SRCOOL5KWRM42U is a factory-assembled 42U deep rack with a pre-installed 5.5 kW direct-expansion cooling unit at the bottom. Single-phase 208 V power and a hard-wire connection with an optional NEMA L6-30P cable mean no separate HVAC installation is required. It targets server rooms and edge sites that need immediate cold-aisle cooling without building infrastructure work.

27U Usable Space With Optimised Airflow

Only 27U remain for equipment because the cooling module occupies the lower portion of the rack. Pre-installed 1U blanks force 470 CFM of conditioned air through the IT gear rather than around it, maintaining consistent intake temperatures during continuous operation. The 1.2 kg R410a charge supports steady heat removal at the rated 18,766 BTU per hour without short-cycling.

Remote Management Via SNMP and Touchscreen

A built-in network management card provides SNMP monitoring and control around the clock, while a 7-inch colour touchscreen on the unit allows local commissioning and diagnostics. The steel enclosure ships fully assembled at 90.47 by 29.13 by 52.76 inches, so the rack is ready to accept equipment once power is connected.

Highlights

  • Self-contained cooling removes need for separate HVAC installation
  • 5 kW capacity handles dense server loads in edge sites
  • 470 CFM airflow directs cold air through 27U usable space
  • Built-in SNMP card enables 24/7 remote monitoring and control
  • 7-inch touchscreen simplifies commissioning and diagnostics on site

Specifications

BrandTripp Lite by Eaton
ModelSRCOOL5KWRM42U
ColorBlack
SpecificationsINPUT
Input Phase: Single-Phase
Electrical Consumption (Max): 5500 Watts
Nominal Input Voltage(s) Supported: 208V AC
Nominal Input Voltage Description: 208V AC 60 Hz
Input Connection Type: Hardwire, Optional 12ft. Cable with L6-30P included
Input Plug Features: Hardwire
Voltage Compatibility (VAC): 208
Input Frequency: 60 Hz
Input Plug Type: NEMA L6-30P
OUTPUT
Frequency Compatibility: 60 Hz
COOLING
Airflow: 470 CFM
Cooling Type: Active
Cooling Type Details: Direct Expansion (DX) refrigerant based
Cooling Capacity (BTUs): 18766
Cooling Capacity (kW): 5.5
Refrigerant: R410a (Environmen
Shipping weight354.01 kg
Package size2298 × 1340 × 740 mm

Questions about this item

How much heat and power does the 5.5 kW cooling unit add to the room when it runs continuously?

The unit draws up to 5500 Watts at 208V single-phase and removes 18,766 BTU per hour from the rack, so the room must handle both the IT load and the unit's own electrical consumption.

What electrical supply and connection must already be in place before the rack arrives?

A 208V AC, 60 Hz single-phase circuit with a NEMA L6-30P receptacle or hardwire point is required; a 12 ft cable with L6-30P plug is included for the latter option.

Will my existing 42U deep servers fit in the 27U of usable space left after the cooling unit is installed?

The rack accepts devices up to 42.95 inches deep, but only 27U of vertical space remains above the pre-installed cooling module, so equipment taller than 27U will not fit.

New to this? Buying server hardware with crypto — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.