Eaton EVMAGU23X Managed PDU 3-Phase 42 Outlets 72-Inch 0U Vertical
Three-phase managed PDU with 42 outlets, universal 100-415V input and 72-inch vertical mounting
- TypeSee Description
- Managed power distribution with outlet-level monitoring
- Three-phase and single-phase input flexibility up to 415 V
- 42 IEC outlets in a 72-inch 0U vertical chassis
- Universal hardwire input supports 16–63 A service ratings
- Input cable sold separately for custom length and plug choice
Universal-input managed PDU
The Eaton EVMAGU23X is a G4 managed power distribution unit that accepts single-phase or three-phase feeds from 100 V to 415 V. Forty-two outlets provide dense rack power for servers, switches and storage arrays in data-centre and colocation environments.
Vertical 0U mounting and hardwire input
The 72-inch 0U vertical chassis mounts in the rack’s zero-U space, leaving horizontal U positions free for compute gear. A universal hardwire input allows on-site termination to match local supply, while the single- and three-phase compatibility lets the same unit serve 208 V, 230 V or 415 V feeds without re-cabling.
Continuous monitoring up to 63 A
Metered inlet and outlet sensors report real-time current, voltage and power factor across all phases, enabling capacity planning and overload alerts during sustained loads. The 63 A maximum rating supports high-density deployments without nuisance tripping, and the management interface integrates with DCIM tools for long-term trend analysis.
Highlights
- Managed power distribution with outlet-level monitoring
- Three-phase and single-phase input flexibility up to 415 V
- 42 IEC outlets in a 72-inch 0U vertical chassis
- Universal hardwire input supports 16–63 A service ratings
- Input cable sold separately for custom length and plug choice
Specifications
| Brand | Eaton |
|---|---|
| Type | See Description |
| Shipping weight | 6.85 kg |
| Package size | 587 × 511 × 89 mm |
Questions about this item
What is the maximum input current the PDU can handle before overload protection trips?
The unit is rated for up to 63 A on the universal hard-wire input.
Does the managed PDU include active cooling that could add noise in a 24-hour server room?
No fan or active cooling is mentioned; the vertical 0U chassis relies on passive airflow.
Since the input cable is sold separately, what hard-wire connection must the installer provide on site?
A qualified electrician must terminate a 3-phase or single-phase feed rated up to 63 A to the universal input terminals.