Eaton
Eaton 9SX3000 3000 VA 2700 W 120 V Tower UPS
Tower online UPS delivering 3000 VA and 2700 W of true sinewave power with five outlets and up to 17 minutes runtime at half load
- Input Voltage Range100V AC - 138V AC
- Input ConnectionNEMA L5-30P
- VA Rating3000 VA
- Watts2700 Watts
- Output Voltage110 V AC 120 V AC 125 V AC
- Output Frequency50/60 Hz
- 3000 VA capacity supports demanding loads
- True sinewave output protects sensitive equipment
- Five outlets include NEMA L5-30R and four 5-20R
- 17 minutes runtime at half load
- cULus listed, FCC compliant, CE marked
Tower UPS power rating
The Eaton 9SX3000 is a 3000 VA / 2700 W online double-conversion UPS in a tower form factor. It delivers true sinewave output at 110 V, 120 V or 125 V AC with a 50/60 Hz frequency. The unit accepts 100 V to 138 V AC input through a NEMA L5-30P plug and provides five outlets: one NEMA L5-30R and four NEMA 5-20R. It ships with a quick start guide, two 1.8 m IEC C13-C14 jumpers, a serial cable and a USB cable.
Server rooms needing long runtime
This UPS suits installations that require clean sinewave power for sensitive electronics and can tolerate only five minutes of battery at full load or seventeen minutes at half load. Buyers who need extended runtime for multiple servers or network gear should look at units with larger battery capacity or external battery modules.
NEMA L5-30P input connection
The UPS connects to a 30 A locking receptacle, so the site must provide a NEMA L5-30R outlet on a dedicated circuit. If the building only has standard 15 A or 20 A sockets, this unit cannot be plugged in without electrical work.
Highlights
- 3000 VA capacity supports demanding loads
- True sinewave output protects sensitive equipment
- Five outlets include NEMA L5-30R and four 5-20R
- 17 minutes runtime at half load
- cULus listed, FCC compliant, CE marked
Specifications
| Brand | EATON |
|---|---|
| Model | 9SX3000 |
| Input Voltage Range | 100V AC - 138V AC |
| Input Connection | NEMA L5-30P |
| VA Rating | 3000 VA |
| Watts | 2700 Watts |
| Output Voltage | 110 V AC 120 V AC 125 V AC |
| Output Frequency | 50/60 Hz |
| Outlets | 5 |
| Outlet Type | 1 x NEMA L5-30R 4 x NEMA 5-20R |
| Battery Run Time | At full load: 5 Minutes At half load: 17 Minutes |
| Approvals | FCC Compliant, CE Marked, cULus Listed |
| Package Contents | 9SX 3000 VA UPS, Quick Start Guide, 2 x IEC C13-C14 jumpers 1.8m, serial cable, USB cable |
| Shipping weight | 37.88 kg |
| Package size | 574 × 572 × 488 mm |
Questions about this item
How much heat does the 9SX3000 add to a server room when it runs continuously?
The unit delivers 2700 watts of output power. As an online double-conversion UPS it draws more from the wall than it supplies to the load, so the room sees the input power as heat. Ensure the space can handle the continuous thermal load.
What site wiring must already be in place for the NEMA L5-30P input plug?
A dedicated 30 A, 120 V circuit terminated in a NEMA L5-30R receptacle is required. The UPS will not operate from a standard 15 A or 20 A wall outlet.
Can I connect legacy IEC C13 equipment directly to the 9SX3000?
The UPS provides one NEMA L5-30R and four NEMA 5-20R outlets. Two 1.8 m IEC C13-C14 jumpers are included so you can adapt two of the 5-20R outlets for C14 inlets.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Micro Connectors CAT6 RJ45 Modular Plug 50 Pack
- RJ45 Connectors
Enfain RJ45 male to female extension cable 90° down angle 1.5 m 28AWG
- 1.5 m