Rack-mountable double-conversion UPS delivers 1000 VA and 800 W through eight NEMA 5-15R outlets with 4-minute full-load runtime
- International Version120V
- Input Voltage Range100 - 125V
- Input Frequency40 - 70 Hz
- Input ConnectionNEMA 5-15P
- VA Rating1000 VA
- Watts800 Watts
- Online double-conversion topology delivers clean sine-wave power
- Configurable 100/110/115/120/125 V output matches sensitive equipment
- Eight NEMA 5-15R outlets support multiple rack devices
- 4 min full-load / 11.5 min half-load runtime protects critical loads
- USB and serial ports enable automated monitoring and shutdown
Double-Conversion Online UPS
The CyberPower OL1KRM is a rack-mountable uninterruptible power supply that uses double-conversion online topology to deliver clean sine-wave output. It accepts 100 to 125 VAC input at 40 to 70 Hz and provides configurable output at 100, 110, 115, 120 or 125 VAC within two percent regulation. Eight NEMA 5-15R outlets supply up to 800 watts or 1000 VA from a single NEMA 5-15P input.
Suited For And Not Suited For
This unit suits network closets, server racks and workstations that require continuous voltage regulation and zero transfer time during power events. USB and serial ports enable management integration. Buyers needing longer battery runtime at full load or higher wattage capacity should consider larger models. Environments outside the zero to forty degree Celsius operating range or requiring non-standard outlet types are not a fit.
Capacity And Headroom
At full 800-watt load the internal sealed lead-acid batteries provide four minutes of runtime, extending to 11.5 minutes at half load. Recharge from empty to ninety percent takes four hours. Overload protection allows brief excursions to 130 percent for twelve seconds in line mode before bypass, and to 150 percent for two seconds before shutdown. Surge energy rating is 710 joules.
Highlights
- Online double-conversion topology delivers clean sine-wave power
- Configurable 100/110/115/120/125 V output matches sensitive equipment
- Eight NEMA 5-15R outlets support multiple rack devices
- 4 min full-load / 11.5 min half-load runtime protects critical loads
- USB and serial ports enable automated monitoring and shutdown
Specifications
| Brand | CyberPower |
|---|---|
| Series | Essential Online UPS |
| Model | OL1KRM |
| International Version | 120V |
| Input Voltage Range | 100 - 125V |
| Input Frequency | 40 - 70 Hz |
| Input Connection | NEMA 5-15P |
| VA Rating | 1000 VA |
| Watts | 800 Watts |
| Output Voltage | 100/110/115/120/125 VAC +/- 2% (configurable) |
| Outlets | 8 |
| Outlet Type | 8 x NEMA 5-15R |
| Battery Type | Sealed Lead Acid |
| Battery Run Time | 4 min Full Load / 11.5 min Half Load |
| Battery Recharge Time | 4 Hours (0% to 90% charged) |
| Battery Replaceable | RB1270X2G |
| Alarms | Battery Mode Low Battery Overload UPS Fault |
| Interface Port | USB, Serial |
| Approvals | UL 1778 CSA C22.2 NO.107.3 FCC Part 15 Class B |
| Rackmountable | Yes |
| Surge Energy Rating | 710 Joules |
| Protection | UPS Output Cut Off Immediately or Input Fuse Circuit Breaker Protection Overload Protection: Line Mode: 102% to 130% load for 12s - bypass Line Mode: 131% to 150% load for 2 s - bypass >150% load 300ms -no output Battery Mode: 102% to 130% load for 12 s - shutdown Battery Mode: >130% for 2 s -shutdown Bypass Mode: 102% to 110% warning Bypass Mode: 111% to 130% load for 5min - no output Bypass Mode: 131% to 150% 16s - no output >150% for 300ms - no output |
| Temperature | Operating Temperature: 32 - 104 °F (0 - 40 °C) Storage Temperature: 5 - 113 °F (-15 - 45 °C) |
| Humidity | Operating Relative Humidity: 0 - 0.9 % (non-condensing) Storage Relative Humidity: 0 - 0.95% (non-condensing) |
| Dimensions | 3.41" x 17.05" x 11.22" |
| Weight | 26.46 lbs. |
| Shipping weight | 15.80 kg |
| Package size | 560 × 390 × 240 mm |
Questions about this item
What input plug does the OL1KRM need from my wall circuit?
The unit ships with a NEMA 5-15P input cord, so a standard 120 V 15 A receptacle is required.
Will my older 100 V equipment run safely on the configurable output?
Yes, the output can be set to 100 V ±2%, matching legacy 100 V gear while the UPS accepts 100–125 V input.
How do I confirm the double-conversion topology is active after installation?
Connect the USB or serial port and use the management software to verify the UPS reports Online mode with output voltage regulated to the selected 100/110/115/120/125 V setting.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Micro Connectors CAT6 RJ45 Modular Plug 50 Pack
- RJ45 Connectors
Enfain RJ45 male to female extension cable 90° down angle 1.5 m 28AWG
- 1.5 m