APC
APC Smart-UPS SMT1000RMI2UC 1.0 kVA 700 W 2U 230V UPS
Provides 1.0 kVA / 700 W battery backup with six IEC outlets, LCD interface and USB, serial plus SmartSlot connectivity
- International Version230V
- Input Voltage RangeInput voltage range for main operations: 160 - 286V Input vo
- Input Frequency50/60 Hz +/- 3 Hz (auto sensing)
- Input ConnectionIEC-320 C14
- VA Rating1.0 kVA
- Watts700 Watts
- 0 kVA and 700 W power rating supports critical equipment
- Six battery-backup outlets keep servers running during outages
- LCD display enables local configuration and status monitoring
- 459-joule surge rating protects connected devices from transients
- Recharges in three hours for rapid recovery after discharge
Rack-mount 1.0 kVA UPS for 230V environments
The APC Smart-UPS SMT1000RMI2UC delivers 1.0 kVA and 700 Watts of battery-backed power in a 2U rack-mount form factor. It accepts an input range of 160 to 286V with an adjustable window of 151 to 302V at 50 or 60 Hz. Six IEC outlets supply 230V output to connected servers, networking gear or storage arrays.
Step up from desktop units when runtime matters
This model replaces smaller tower or 1U backups that cannot sustain a full rack load during an outage. The jump is worth it when you need 8.7 minutes at 700 W or 31.3 minutes at half load to ride through short interruptions or trigger graceful shutdowns. A three-hour recharge restores full capacity for the next event.
Handles a full 700 W load
At maximum draw the unit runs for 8.7 minutes, giving enough headroom for orderly power-down scripts. At lighter loads the 31.3-minute window covers most brief utility faults. It is not suited for workloads that demand hours of autonomy or for installations requiring higher VA ratings than 1.0 kVA.
Highlights
- 0 kVA and 700 W power rating supports critical equipment
- Six battery-backup outlets keep servers running during outages
- LCD display enables local configuration and status monitoring
- 459-joule surge rating protects connected devices from transients
- Recharges in three hours for rapid recovery after discharge
Specifications
| Brand | APC |
|---|---|
| Series | Smart-UPS |
| Model | SMT1000RMI2UC |
| International Version | 230V |
| Input Voltage Range | Input voltage range for main operations: 160 - 286V Input voltage adjustable range for mains operation: 151 - 302V |
| Input Frequency | 50/60 Hz +/- 3 Hz (auto sensing) |
| Input Connection | IEC-320 C14 |
| VA Rating | 1.0 kVA |
| Watts | 700 Watts |
| Output Voltage | 230V |
| Output Frequency | 50/60Hz +/- 3 Hz |
| Outlets | 6 |
| Outlet Type | 4 x IEC 320 C13 (Battery Backup) 2 x IEC Jumpers (Battery Backup) |
| Battery Run Time | Full Load: 8.7 Minutes Half Load: 31.3 Minutes |
| Battery Recharge Time | 3 Hour(s) |
| Alarms | Alarm when on battery, distinctive low battery alarm, configurable delays |
| Interface Port | RJ-45 Serial , SmartSlot , USB |
| Approvals | CSA, EAC, EN/IEC 62040-1, EN/IEC 62040-2, RCM, UL 1778, VD, RoHS |
| Surge Energy Rating | 459 Joules |
| Features | Smarter productivity with ability to tailor to your specific application needs Intuitive LCD interface provides clear information with the ability to configure the UPS locally with easy to use navigation keys. Over 15 different programmable settings including switched outlet group control allow for application specific settings, thresholds and notifications. Peace of mind that comes with full equipment compatibility and reliability of a leader Provides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety a |
| Dimensions | 3.39" x 17.00" x 18.78" |
| Weight | 62.13 lbs. |
| Package Contents | Smart-UPS SMT1000RMI2UC, CD with software , Documentation CD , Installation guide , Rack Mounting support rails , Smart UPS signalling RS-232 cable , USB cable |
| Shipping weight | 29.26 kg |
| Package size | 533 × 495 × 152 mm |
Questions about this item
What rack depth and clearance does the 2U Smart-UPS SMT1000RMI2UC need for its IEC-320 C14 input and six outlets?
The 2U unit mounts in a standard rack; allow enough rear depth for the IEC-320 C14 inlet and the six IEC outlets (four C13 plus two jumpers) plus cable bend radius.
Which cable do I connect first when installing the SMT1000RMI2UC, and what LCD menu must I set before loading equipment?
Connect the IEC-320 C14 input to a 230V supply, then use the front LCD navigation keys to confirm output voltage is 230V and frequency auto-sensing is enabled before attaching loads to the six battery-backup outlets.
How often should I replace the internal battery in the SMT1000RMI2UC, and what runtime loss signals it is time?
Expect roughly three to five years; when a full-load runtime drops well below the rated 8.7 minutes or a half-load runtime falls far short of 31.3 minutes, plan a battery swap.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Micro Connectors CAT6 RJ45 Modular Plug 50 Pack
- RJ45 Connectors
Enfain RJ45 male to female extension cable 90° down angle 1.5 m 28AWG
- 1.5 m