APC
APC AP7582 Basic Rack PDU 2U 30A 120V (12)5-20
Basic 2U rack power distribution unit supplying 30 A at 120 V through twelve 5-20 outlets
- Distributes power to twelve 5-20 outlets
- Handles 30 A at 120 V for dense racks
- 2U horizontal form factor fits standard enclosures
- InfraStruXure Certified for managed infrastructure
- Tool-less vertical mounting in NetShelter VX rear channel
APC Basic Rack PDU 2U 30A 120V
The APC AP7582 is a Basic Rack Power Distribution Unit designed to deliver 120 V power to rack-mounted equipment. It occupies 2U of horizontal rack space and provides twelve NEMA 5-20R outlets fed by a single 30 A input.
Suited for 120 V server racks needing dense outlet
This unit fits administrators who need twelve 20 A receptacles in a compact 2U form factor for 120 V environments. It is not intended for installations requiring metered or switched power management, higher input voltages, or vertical zero-U mounting without the NetShelter VX rear channel.
Twelve 5-20R outlets on a 30 A 120 V feed
The PDU comfortably powers up to twelve devices drawing up to 20 A each while the aggregate load stays within the 30 A supply rating. Headroom ends when combined draw approaches the 30 A limit, at which point the upstream breaker becomes the constraining factor.
Highlights
- Distributes power to twelve 5-20 outlets
- Handles 30 A at 120 V for dense racks
- 2U horizontal form factor fits standard enclosures
- InfraStruXure Certified for managed infrastructure
- Tool-less vertical mounting in NetShelter VX rear channel
Specifications
| Brand | APC |
|---|---|
| Model | AP7582 |
Questions about this item
What rack infrastructure is required to mount this 2U PDU without tools?
It mounts vertically in the rear channel of a NetShelter VX enclosure.
How does the 30 A, 120 V input connect to an existing facility circuit?
The unit draws up to 30 A at 120 V, so the branch circuit and breaker must support that rating.
How can I verify the PDU is delivering power to connected equipment after installation?
Check that each of the twelve 5-20R outlets shows voltage and that attached devices power on normally.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
YOUHUA SATA Cable Kit 2×Data 0.48 m 2×Power 0.16 m
- Sata cables: 2 SATA…
Micro Connectors SATA cable 40 inches straight to right angle locking latch black 3 pack
- Black