WUQ
WUQ 19" 1U Fiber Patch Panel 48 Fibers 2 Splice Trays
A 19-inch 1U rack-mount fiber enclosure holds up to 48 fibers in two splice trays with a black powder-coat metal finish
- TypeRack Mount Cabinet
- 19-inch rack mount fits standard cabinets
- 1U height saves vertical space in dense racks
- 48-fiber capacity with two splice trays included
- Sturdy metal construction with black powder-coat finish
- Conforms to YD/T926, ISO/IEC 11801 and TIA/EIA-568-B standards
19-inch 1U rack-mount fiber enclosure
This 19-inch 1U fiber patch panel fits standard server racks and cabinets. It provides a secured enclosure space for terminating and organising fiber connections in data centres, LAN, WAN and telecommunication networks. The unit conforms to YD/T926, ISO/IEC 11801 and TIA/EIA-568-B standards. Black powder-coated metal construction ensures durability for premise installations.
Passive thermal management with zero power draw
The enclosure operates without fans or active cooling, so it adds no noise or electrical load to the rack. Heat dissipates naturally through the vented metal chassis during normal operation. No external power supply or internal circuitry is required. This passive design suits environments where silent, maintenance-free operation is expected.
Two splice trays enable 48-fiber capacity
Two included splice trays with removable protective jackets support a maximum of 48 fibers. The trays accommodate tighter bend-radius requirements and high-density installations. LGX-compatible loading allows selection of different connector types and lengths. The plug-and-play layout simplifies deployment across CATV, instrument and communication systems.
Highlights
- 19-inch rack mount fits standard cabinets
- 1U height saves vertical space in dense racks
- 48-fiber capacity with two splice trays included
- Sturdy metal construction with black powder-coat finish
- Conforms to YD/T926, ISO/IEC 11801 and TIA/EIA-568-B standards
Specifications
| Type | Rack Mount Cabinet |
|---|
Questions about this item
How do I mount the 1U panel in a 19 inch rack and what step is often missed?
Fasten the panel to the rack rails with four cage nuts or screws; the step often missed is securing both front and rear flanges so the 46 mm depth does not flex under cable load.
What maintenance will the two splice trays need over time?
Inspect the trays for dust on the fiber ends and clean with a lint-free wipe and isopropyl alcohol; replace any tray whose hinges no longer latch securely.
Which limit appears first when 48 fibers run at high throughput for long periods?
The 1U height restricts airflow, so connector temperature rise becomes the first limit; keep front-to-rear airflow clear and monitor patch-cord bend radius at the tray spools.
New to this? Buying server hardware with crypto — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Lenovo 4X60N04886 Nvidia Quadro P5000 16GB GDDR5X ai accelerator card
- GDDR5
NVIDIA H200 NVL AI Accelerator Card 141GB HBM3e PCIe 5.0 x16 900-21010-0040-000
- PCI Express 5.0 x16
- NVIDIA