Vertiv
Vertiv PSI5-1500RT120LIN 1500VA 1350W Rack/Tower UPS with SNMP Card
A 1500VA rack or tower UPS with lithium-ion batteries, automatic voltage regulation, pure sine-wave output and an included SNMP card for remote management
- 1500VA capacity protects servers and networking gear during outages
- 1350W output delivers pure sine wave power on battery
- Lithium-Ion battery lasts more than double traditional VRLA life
- Automatic voltage regulation corrects fluctuations without using battery
- Rotating LCD display works in both rack and tower setups
1500VA Lithium-Ion UPS for Edge IT
The Vertiv PSI5-1500RT120LIN is a line-interactive uninterruptible power supply rated at 1500VA and 1350W. It uses lithium-ion cells that deliver more than double the service life of traditional VRLA batteries. The unit ships with a factory-installed SNMP card for remote network management. Pure sine wave output on battery protects sensitive servers and networking gear.
Suits Rack or Tower Deployments Needing Long Runtime
Automatic voltage regulation corrects brownouts and over-voltages from 75VAC to 146VAC without draining the battery. Output voltage defaults to 120VAC and can be set to 100, 110, 115 or 125VAC to match local equipment. The rotating LCD readout remains readable whether the chassis is mounted in a rack or stood upright as a tower. Buyers who need extended runtime beyond 18 minutes at half load or 8 minutes at full load should evaluate higher-capacity units.
1350W Real Power Decides the Load Limit
The 1350W rating is the single figure that determines how many watts of connected gear the UPS can support during an outage. If the total draw of your servers, switches and storage exceeds this value, the unit will overload and shut down. Size the protected load against 1350W, not the 1500VA apparent-power number, to ensure reliable operation.
Highlights
- 1500VA capacity protects servers and networking gear during outages
- 1350W output delivers pure sine wave power on battery
- Lithium-Ion battery lasts more than double traditional VRLA life
- Automatic voltage regulation corrects fluctuations without using battery
- Rotating LCD display works in both rack and tower setups
Specifications
No published specifications for this item yet.
Questions about this item
How long does the battery last at full load before the UPS shuts down?
The UPS provides 8 minutes of runtime at full 1350 W load before battery depletion.
What is the typical heat output when the unit runs continuously at full capacity?
At 1350 W output the UPS dissipates roughly 150 W as heat, so expect warm exhaust air and fan noise after extended full-load operation.
Which input voltage range must the site supply for the UPS to operate without switching to battery?
The unit accepts 75 V to 146 V AC; outside that range it transfers to battery and uses its AVR circuitry to maintain 120 V output.