Vertiv
Vertiv PD2-109 2-Outlet PDU 2×NEMA L14-30R 60A 208V/120V
Two-outlet PDU with dual NEMA L14-30R receptacles accepts 60 A hard-wired 208 V/120 V input for GXT4 8-10 kVA UPS maintenance bypass
- TypeConsumer Electronics
- FeaturesProduct Type:PDU Product Name:PD2-109 2-Outlets PDU Output R
- Weight4.40 lb
- Delivers 60 A three-phase power for high-density rack loads
- Two NEMA L14-30R outlets supply both 208 V and 120 V circuits
- Hardwire 4-wire input enables direct panel connection without plug adapters
- Maintenance bypass keeps connected equipment online during UPS service
- Lightweight 4.40 lb chassis simplifies rack mounting and cable routing
Maintenance bypass PDU
The Vertiv PD2-109 is a power distribution unit that provides a maintenance bypass for Liebert GXT4 8-10kVA UPS systems. It allows technicians to service or replace the UPS without interrupting power to connected equipment. The unit accepts a hardwired 4-wire input with two phases, neutral and ground. It is built for commercial and industrial environments that require continuous uptime.
Hardwired input and 60 A rating
The PDU connects directly to a 208V/120V three-phase supply rated at 60 A through a 4-wire hardwired connector. Two NEMA L14-30R output receptacles distribute power to the load. The enclosure weighs 4.40 lb and mounts in a standard rack or on a wall. Passive power distribution means no active cooling is required and the unit adds no audible noise to the installation.
Two NEMA L14-30R outlets
This model provides exactly two NEMA L14-30R receptacles, so it suits installations that need dual 30 A locking outlets from a single 60 A feed. Sites requiring more than two outlets, a different receptacle type, or a lower input current rating cannot use this PDU. The part is listed for GXT4 8-10kVA models and was first offered in 2024.
Highlights
- Delivers 60 A three-phase power for high-density rack loads
- Two NEMA L14-30R outlets supply both 208 V and 120 V circuits
- Hardwire 4-wire input enables direct panel connection without plug adapters
- Maintenance bypass keeps connected equipment online during UPS service
- Lightweight 4.40 lb chassis simplifies rack mounting and cable routing
Specifications
| Brand | Liebert |
|---|---|
| Model | PD2-109 |
| Type | Consumer Electronics |
| Features | Product Type:PDU Product Name:PD2-109 2-Outlets PDU Output Receptacles:2 x NEMA L14-30R |
| Weight | 4.40 lb |
| Shipping weight | 4.08 kg |
| Package size | 522 × 302 × 220 mm |
Questions about this item
How is the hard-wire 4-wire input connected, and which step is most often missed?
The 4-wire feed (2PH+N+G) must be landed on the internal terminal block by a qualified electrician; the step most often missed is torquing each lug to the specified value and verifying phase rotation before energising.
What maintenance or replacement will the two NEMA L14-30R outlets need over time?
Inspect the L14-30R contacts annually for discolouration or looseness; replace any receptacle that shows pitting or fails a clamp-force test to maintain reliable 30 A connections.
What is the first limit reached when the PDU runs continuously at full 60 A load?
The 60 A input rating is the hard ceiling; sustained draw at that level will trip the upstream breaker before any internal component reaches a thermal limit.