We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Vertiv

Vertiv MP2-120C PDU 8×5-20R 3×5-20P 16A 120V 10ft

SKU CH-KG01-VVKGY MPN MP2-120C

Switched PDU with eight NEMA 5-20R outlets, three NEMA 5-20P inputs, 16 A at 120 V, 10 ft cord, 19-inch rack-mountable

  • TypeSwitched
  • Input Voltage120 V AC Single-phase
  • Input Connector(s)5-20P
  • Cord Length10 ft. Power Cord
  • Output Voltage120 V AC
  • Output Connector(s)5-20R
  • Maintenance bypass keeps equipment powered during UPS service
  • Eight NEMA 5-20R outlets supply 120 V AC to connected loads
  • Three NEMA 5-20P inputs support 16 A maximum current
  • Ten-foot power cord allows flexible rack placement
  • 19-inch rack, floor or wall mounting brackets included

Maintenance bypass PDU

The Vertiv MP2-120C is a switched power distribution unit that provides a maintenance bypass for compatible UPS systems. It routes utility power directly to connected equipment while the UPS is serviced or replaced, preventing interruption to critical loads. The unit supports single-phase 120 V AC input and output with a maximum current of 16 A. Three NEMA 5-20P input plugs and eight NEMA 5-20R output receptacles handle the power connections.

Rack or wall-mount installations

This PDU suits environments where a UPS up to 3 kVA must remain online during maintenance, such as server rooms, network closets or edge sites. It ships with brackets for 19-inch rack, floor or wall mounting, measuring 3.5 inches high, 17.0 inches wide and 3.5 inches deep. Sites that do not require maintenance bypass switching, or that operate on voltages other than 120 V AC, should consider a different power distribution approach.

Three NEMA 5-20P input plugs

The defining specification is the trio of NEMA 5-20P input connectors, which must match the UPS or facility receptacles available on site. If the installation provides only a single input connection or uses a different plug type, this unit will not integrate without additional adapters or rewiring. The 10-foot cord length and 16 A rating are fixed by this input configuration.

Highlights

  • Maintenance bypass keeps equipment powered during UPS service
  • Eight NEMA 5-20R outlets supply 120 V AC to connected loads
  • Three NEMA 5-20P inputs support 16 A maximum current
  • Ten-foot power cord allows flexible rack placement
  • 19-inch rack, floor or wall mounting brackets included

Specifications

BrandLiebert
ModelMP2-120C
TypeSwitched
Input Voltage120 V AC Single-phase
Input Connector(s)5-20P
Cord Length10 ft. Power Cord
Output Voltage120 V AC
Output Connector(s)5-20R
FeaturesHigher Availability
Provides utility power to attached equipment when switched to maintenance bypass mode.
Allows UPS maintenance or replacement of the UPS without discontinuing power to critical equipment.
Flexibility
Easily installed - the UPS and utility power are both connected to the MicroPOD with the supplied cords.
Allows scheduled UPS maintenance to ensure continuous uptime without having to shut down protected equipment.
Rotary switch with indicators make the unit simple to operate.
Plug-and-play connectability for both input and output.
Compatible with any brand of UPS syst
Dimensions3.5" Height x 17.0" Width x 3.5" Depth
Shipping weight4.54 kg
Package size457 × 191 × 178 mm

Questions about this item

How much heat or fan noise does the MP2-120C add when it runs continuously in a 19-inch rack?

The MP2-120C is a passive maintenance-bypass switch with no fans or active cooling, so it produces no audible noise and adds negligible heat beyond the normal warm-up of its 16 A busbars and eight NEMA 5-20R outlets.

What UPS inlet and outlet plugs must already be on site for the MP2-120C to connect without adapters?

The unit requires three NEMA 5-20P input cords from the utility or UPS sources and provides eight NEMA 5-20R receptacles for the attached loads, all rated 120 V AC, 16 A maximum.

Will the MP2-120C work with the older Liebert GXT2 3 kVA UPS we still run?

Yes — the MP2-120C is designed for Vertiv Liebert PSI and GXT series UPS units up to 3 kVA, so a GXT2 3 kVA fits the supported range and can be bypassed for maintenance without cutting power to the eight 5-20R outlets.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.