Vertiv
Vertiv GXT5-750LVRT2UXL UPS 120 V 750 VA 750 W 2U
Rack-mountable UPS delivers 750 W from 120 V input with six output connectors, RS-232 and USB management
- 750 W continuous power protects critical rack equipment
- 750 VA apparent capacity handles high inrush loads
- 120 V input matches standard North American circuits
- RS-232 and USB ports enable local management
- Six output connectors distribute power to multiple devices
Rack-mountable UPS for 120 V environments
The Vertiv GXT5-750LVRT2UXL is a new lead-acid uninterruptible power supply designed for rack or external mounting in a 2U form factor. It delivers 750 VA and 750 W of continuous output at 120 V AC. The unit suits servers, network gear and edge equipment that require clean, battery-backed power in standard IT racks. It is not intended for loads that exceed its 750 W rating or for installations needing a different input voltage.
Capacity and headroom at 750 W
The UPS supports a full 750 W load, so it comfortably handles single workstations, switches or small server nodes within that power envelope. Runtime scales with the connected load; lighter draws extend battery time while heavier draws reduce it to the minimum reserve. Six output connectors allow multiple devices to share the same backup circuit. Loads above 750 W will trip the unit, so it cannot support larger multi-node racks or high-density blades.
RS-232 and USB management interfaces
Communication is provided through RS-232 and USB ports for monitoring, graceful shutdown and firmware updates. These two interfaces are the only management pathways built into the unit. Environments that rely solely on network-based management cards or other protocols will need a different model or an accessory not included here.
Highlights
- 750 W continuous power protects critical rack equipment
- 750 VA apparent capacity handles high inrush loads
- 120 V input matches standard North American circuits
- RS-232 and USB ports enable local management
- Six output connectors distribute power to multiple devices
Specifications
No published specifications for this item yet.
Questions about this item
Will the 750 VA UPS protect my older 120 V server gear through its six output connectors?
Yes, the unit delivers 750 W at 120 V across six rear outlets, so legacy rack equipment within that load limit stays powered during an outage.
How can I confirm the UPS is communicating correctly after installation?
Connect the RS-232 or USB cable to your management host; the monitoring software will show real-time load, battery status and input voltage once the link is active.
What ships with the 2U rack-mount UPS and what must I source separately?
The box includes the UPS module, rack ears and communication cables; input cord, output cords and any network management card are purchased separately.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.