We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Vertiv
Delivers 3000VA pure sine-wave backup with seven configurable outlets and an included network card in a 2U rack/tower form factor
The Vertiv GXT5-3000LVRT2UXLN is a 3000VA, 2700W online double-conversion UPS that delivers pure sine-wave output at 120V. It mounts in a 2U rack or stands as a tower and includes an RDU120 network card for remote monitoring. Seven outlets, one NEMA L5-30R and six NEMA 5-20R, support a range of IT loads.
This unit fits network closets, edge sites and small server rooms that need runtime measured in minutes rather than hours. Buyers who require extended battery autonomy at full load should look at larger-capacity UPS models or external battery cabinets. Sites without a NEMA L5-30P supply will need an alternative input connection.
At half load the internal VRLA batteries provide 12.6 minutes of runtime; at full load the figure drops to 4 minutes. The UPS accepts a wide 60-150V input window and auto-senses 40-70Hz, so it stays online through prolonged voltage sags without draining the battery. Operating temperature range is 32°F to 104°F.
| Brand | Vertiv |
|---|---|
| Series | Liebert |
| Model | GXT5-3000LVRT2UXLN |
| International Version | 120V |
| Input Voltage Range | 60-150V |
| Input Frequency | 40-70Hz; Auto Sensing |
| Input Connection | NEMA L5-30P |
| VA Rating | 3000VA |
| Watts | 2700W |
| Output Voltage | 110/115/120/125VAC; (user-configurable); +/-3% |
| Outlets | 7 |
| Outlet Type | 1 x NEMA L5-30R, 6 x NEMA 5-20R |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Battery Run Time | Half Load: 12.6 min Full Load: 4 min |
| Approvals | UL 1778 4th Edition and CSA 22.2 No 107.3 |
| Temperature | Operating Temperature: 32°F - 104°F (0°-40°) Storage Temperature: -4°F - 140°F (-20°-60°) |
| Humidity | 0% to 95%, non-condensing |
| Dimensions | 3.4" x 16.9" x 18.5" |
| Weight | 47.5 lbs. |
| Package Contents | with RDU120 Network Card |
| Shipping weight | 35.50 kg |
| Package size | 719 × 566 × 254 mm |
The UPS requires a NEMA L5-30P receptacle on a 120 V circuit capable of supplying up to 24 A.
Yes, the 5-20R outlets accept both 5-15P and 5-20P plugs, so older 15 A equipment connects directly.
Log into the card's web interface or SNMP manager; it will display real-time voltage, load percentage, battery status and alarm logs.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
Same shelf, same checkout — eight coins and a 30-minute rate lock.
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
Pick the language the site speaks to you in.
No language matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?