We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Vertiv

Vertiv GXT5-2000LVRT2UXL 2000VA 1800W 120V 2U UPS

SKU CH-ETS9-F5RNF MPN GXT5-2000LVRT2UXL

Double-conversion UPS delivers 2000VA 1800W through seven outlets with zero transfer time

  • International Version120V
  • Input Voltage Range60-150V
  • Input Frequency40-70Hz; Auto Sensing
  • Input ConnectionNEMA L5-20P or 5-20P plug (5-20P adapter included)
  • VA Rating2000VA
  • Watts1800W
  • Double-conversion topology delivers clean power with zero transfer time
  • 2000 VA / 1800 W capacity supports mission-critical IT loads
  • Seven outlets — one L5-20R and six 5-20R — connect diverse equipment
  • User-configurable output voltage (110/115/120/125 V ±3 %) matches local requirements
  • Energy Star certified online UPS in a compact 2U rack/tower form factor

2U Rack-Tower UPS for Mission-Critical Loads

The Vertiv GXT5-2000LVRT2UXL is a double-conversion online UPS rated at 2000VA and 1800W for 120V environments. Its 2U rack-tower form factor fits standard enclosures while the colour graphic LCD provides clear status at a glance. Designed for mission-critical IT equipment, it delivers pure sine-wave output with zero transfer time during power events.

Input Range and Outlet Constraints

The unit accepts an input voltage window of 60-150V at 40-70Hz with auto-sensing frequency. It connects via a NEMA L5-20P plug and includes a 5-20P adapter for flexibility. Outputs are limited to one NEMA L5-20R and six NEMA 5-20R receptacles, so devices requiring other plug types need external adapters. Operating temperature spans 32°F to 104°F.

Battery Runtime at Load Levels

Valve-regulated lead-acid batteries provide 12.3 minutes of runtime at half load and 4 minutes at the full 1800W rating. This window supports graceful shutdown of connected servers and network gear but does not sustain extended operation. The UPS meets UL 1778 4th Edition and CSA 22.2 No 107.3 approvals for safety compliance.

Highlights

  • Double-conversion topology delivers clean power with zero transfer time
  • 2000 VA / 1800 W capacity supports mission-critical IT loads
  • Seven outlets — one L5-20R and six 5-20R — connect diverse equipment
  • User-configurable output voltage (110/115/120/125 V ±3 %) matches local requirements
  • Energy Star certified online UPS in a compact 2U rack/tower form factor

Specifications

BrandVertiv
SeriesLiebert
ModelGXT5-2000LVRT2UXL
International Version120V
Input Voltage Range60-150V
Input Frequency40-70Hz; Auto Sensing
Input ConnectionNEMA L5-20P or 5-20P plug (5-20P adapter included)
VA Rating2000VA
Watts1800W
Output Voltage110/115/120/125VAC; (user-configurable); +/-3%
Outlets7
Outlet Type1 x NEMA L5-20R, 6 x NEMA 5-20R
Battery TypeValve Regulated Lead Acid (VRLA)
Battery Run TimeHalf Load: 12.3 min
Full Load: 4 min
ApprovalsUL 1778 4th Edition and CSA 22.2 No 107.3
TemperatureOperating Temperature: 32°F - 104°F (0°-40°)
Storage Temperature: -4°F - 140°F (-20°-60°)
Humidity0% to 95%, non-condensing
Dimensions3.4" x 16.9" x 18.5"
Weight47.5 lbs.
Shipping weight26.63 kg
Package size617 × 569 × 262 mm

Questions about this item

Should I select the L5-20P or the 5-20P input plug for my circuit?

The unit ships with an L5-20P plug and includes a 5-20P adapter; use L5-20P on a 20 A locking circuit or the adapter on a standard 5-20R receptacle.

What does the 1800 W rating mean for my connected servers?

It is the maximum real power the UPS can deliver continuously; the combined load of all plugged-in equipment must stay at or below 1800 W.

How does the double-conversion topology affect the transfer time when utility power fails?

Double conversion keeps the inverter online at all times, so the transfer time is effectively zero nanoseconds during an outage.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.