We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Tripp Lite

Tripp Lite SRXCOOL12KA 12000 BTU 3.5 kW 230V Portable Server Rack AC Unit

SKU CH-GDT2-HXX45 MPN SRXCOOL12KA

A portable 12000 BTU self-contained air conditioner delivers 3.5 kW close-coupled rack cooling with 57 dB operation on 230 V power

  • TypeAir Conditioners
  • ColorBlack
  • MaterialABS
  • SpecificationNominal Input Voltage (s) Supported: 220V AC; 230V AC; 240V
  • FeaturesPortable Close-Coupled Rack Cooling System Improves Equipmen
  • Included AccessorySRXCOOL12KA Portable Data Center Cooling Unit Louvered front
  • 12,000 BTU cooling protects rack equipment from heat damage
  • 5 kW capacity handles high-density server loads reliably
  • Portable self-contained design enables close-coupled cooling without permanent installation
  • 230V SAA/RCM compliance suits Australian and New Zealand power standards
  • 57 dB sound level keeps noise low in shared environments

Portable Server Rack Cooling

The Tripp Lite SRXCOOL12KA is a self-contained portable air conditioner built for server racks and network cabinets. It delivers 12000 BTU or 3.5 kW of cooling capacity to protect equipment from heat-related failure. The unit operates on 220V, 230V or 240V AC power at 50 or 60 Hz with an IEC Type I plug. It is designed for 230V SAA and RCM markets and suits tower form factor installations.

Thermals Noise and Power

The rotary compressor uses R410a refrigerant with a 22 oz charge and provides active cooling with evaporator airflow of 560 l/s and condenser airflow of 530 l/s. Nominal amp draw ranges from 7 to 10 A across the supported voltage range. Sound level is rated at 57 dB during operation. A built-in dehumidifier removes up to 2.5 liters of moisture per hour to help maintain a stable environment for sensitive hardware.

Bundled Ventilation Kit

Included accessories comprise a louvered front vent insert, duct adapters, a cold-air directional delivery tube and a hot-exhaust removal tube. A window and drop-ceiling heat ventilation kit with adjustable exhaust panels enables flexible heat rejection. The air supply tube measures 70.87 inches and the exhaust tube measures 118.11 inches for routing to external spaces. A touch-sensitive control panel with numerical temperature readout provides direct control.

Highlights

  • 12,000 BTU cooling protects rack equipment from heat damage
  • 5 kW capacity handles high-density server loads reliably
  • Portable self-contained design enables close-coupled cooling without permanent installation
  • 230V SAA/RCM compliance suits Australian and New Zealand power standards
  • 57 dB sound level keeps noise low in shared environments

Specifications

BrandTripp Lite
ModelSRXCOOL12KA
TypeAir Conditioners
ColorBlack
MaterialABS
SpecificationNominal Input Voltage (s) Supported: 220V AC; 230V AC; 240V AC
Input connection type: IEC Type I
Input cord length (ft.): 6
Front panel LEDs: Touch sensitive control panel with multiple LEDs and numerical temperature readout
Form factors supported: Tower
Cooling Capacity: 12,000 BTU / 3.5 kW
Dehumidifier: 2.5 liters / hour
Compressor Type: Rotary
Refrigerant: R410a (Environmentally friendly, Non ozone depleting)
Refrigerant Amount: 22 oz.
Air Flow: Evaporator = 560 l/s / Condenser = 530 l/s
Amp Draw Nominal: 7-10A
Sound Level (Noise): 57 dB
Air Supply Tube Length: 70.87 inches
Air Ex
FeaturesPortable Close-Coupled Rack Cooling System Improves Equipment Performance
SRXCOOL12KA is a portable, compact, self-contained AC cooling unit for server racks.
Designed Specifically for 230V SAA/RCM Markets
12,000 BTU of Cooling Power Protects Your Equipment Against Hazardous High Heat
Rack/Spot Cooling Focuses Cold Air Where It's Most Needed
Built-In Evaporator Ensures No Water Collection Tank to Empty
Add an Optional Remote Management Accessory for 24/7 Monitoring and Control
Designed for Simple Plug-and-Play Installation by Almost Anyone
Included AccessorySRXCOOL12KA Portable Data Center Cooling Unit
Louvered front vent insert
Duct adapters
Cold-air directional delivery tube
Hot-exhaust removal tube
Window/drop-ceiling heat ventilation kit
Adjustable exhaust panels
Self-tapping screw
Owner's manual
Unit Dimension30.63'' x 11.81'' x 19.88''
Unit Weight73.9 lbs.
Shipping Dimension15.00'' x 29.00'' x 34.00''
Shipping weight37.20 kg
Package size864 × 737 × 381 mm

Questions about this item

How do I connect the 1.83 m IEC Type I cord and where do the 70.87 inch supply and 118.11 inch exhaust tubes attach?

Plug the IEC Type I cord into a 230 V outlet, then fit the cold-air delivery tube to the front evaporator vent and the hot-exhaust tube to the rear condenser vent; both tubes slide over the built-in flanges and secure with the included adjustable exhaust panels.

What ongoing care does the R410a rotary compressor and 2.5 L/h dehumidifier need?

Clean or replace the evaporator and condenser filters monthly, empty the condensate tank or run a drain hose continuously, and check the 22 oz refrigerant charge only if cooling drops below 12000 BTU.

At what point does the 57 dB noise or 7–10 A draw limit continuous operation?

The unit is rated for continuous duty at 57 dB and 7–10 A on 208–240 V; the first practical limit is the condensate tank filling at 2.5 L/h, so provide a permanent drain for uninterrupted run time.