Tripp Lite
Tripp Lite SRCOOL24K 24,000 BTU 208/240V Portable Server Rack Air Conditioner
A portable, rack-width unit delivers 24,000 BTU/h of cooling, dehumidification and air filtration to prevent server overheating and downtime
- TypeAir Conditioning Unit
- ColorBlack
- SpecificationNominal Input Voltage(s) Supported: 208V AC; 240V AC Electri
- FeaturesPortable, High-Capacity Cooling Power Produces 24,000 BTU/h
- Unit Dimension38.20" x 20.50" x 21.70"
- Unit Weight175.38 lbs.
- 24,000 BTU/h cooling protects servers from overheating shutdowns
- Portable rack-width chassis fits in 4 sq ft floor space
- Self-contained evaporator removes condensation without floor drain
- Dehumidifies and filters air for better equipment performance
- Efficient close-coupled cooling lowers energy use and operating costs
Portable Rack Air Conditioner
The Tripp Lite SRCOOL24K delivers 24,000 BTU/h of cooling in a portable, rack-width chassis. It is built for server rooms and data centres that need primary, supplemental or backup cooling without permanent installation. The unit prevents equipment shutdowns caused by overheating and temperature fluctuations.
Black ABS Chassis on Casters
The unit measures 38.20" x 20.50" x 21.70" and weighs 175.38 lbs, fitting into just four square feet of floor space. Durable built-in casters allow it to roll into position. A NEMA L6-20P plug on a two-metre cord connects to a standard 208/240V 20A outlet.
Self-Contained Cooling Limits
An integrated evaporator expels condensation through a directional exhaust duct, removing the need for a floor drain or water tank. The unit runs on R410A refrigerant and draws a maximum of 2560 watts. It restarts automatically after a power failure.
Highlights
- 24,000 BTU/h cooling protects servers from overheating shutdowns
- Portable rack-width chassis fits in 4 sq ft floor space
- Self-contained evaporator removes condensation without floor drain
- Dehumidifies and filters air for better equipment performance
- Efficient close-coupled cooling lowers energy use and operating costs
Specifications
| Brand | Tripp Lite |
|---|---|
| Model | SRCOOL24K |
| Type | Air Conditioning Unit |
| Color | Black |
| Specification | Nominal Input Voltage(s) Supported: 208V AC; 240V AC Electrical Consumption: 2560 Watts Max Input Connection Type: NEMA L6-20P Input Cord Length (m): 2 Material of Construction: ABS Form Factors Supported: Tower Dehumidifier: 56.8 L/h Compressor Type: Rotary Refrigerant: R410a (Environmentally friendly, Non ozone depleting) Refrigerant Amount: 42.33 oz. Air Flow: Evaporator = 1077 CFM / Condenser = 1088 CFM Amp Draw Nominal: 13.5A Sound Level (Noise): 65 dB Air Supply Tube Length: 71 inches Air Exhaust Tube Length: 118 inches Air Exhaust Tube Diameter: 5.16 inches |
| Features | Portable, High-Capacity Cooling Power Produces 24,000 BTU/h (7 kW) of cooling capacity in a portable, rack-width chassis Prevents equipment shutdowns, malfunctions and failures caused by overheating and temperature fluctuations Filters and dehumidifies the air to enhance equipment performance Uses environmentally friendly R410A refrigerant, which complies with worldwide standards Efficient close-coupled cooling reduces energy use and operating costs Convenient Operation Adjustable louvers support area cooling applications Flexible dual output ducts aim cold air where it's needed, suc |
| Unit Dimension | 38.20" x 20.50" x 21.70" |
| Unit Weight | 175.38 lbs. |
| Shipping Dimension | 44.10" x 38.50" x 29.35" |
| Shipping Weight | 244.40 lbs. |
| Shipping weight | 69.40 kg |
| Package size | 1168 × 762 × 635 mm |
Questions about this item
What voltage and plug does the SRCOOL24K need, and what current does that cap in practice?
The unit runs on 208 V AC or 240 V AC and uses a NEMA L6-20P plug, which limits it to a 20 A branch circuit.
What floor space and clearance does the 38.20" x 20.50" x 21.70" chassis require to roll into a rack row?
It occupies about 4 square feet of floor space and fits a standard rack-width footprint; allow clearance for the directional exhaust duct.
How is the SRCOOL24K installed, and what step do people often miss?
Roll it on the built-in casters, plug the NEMA L6-20P into a 208/240 V 20 A outlet, and route the exhaust duct — no drain or water tank is needed because the evaporator expels condensation.
New to this? Buying server hardware with crypto — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Lenovo 4X60N04886 Nvidia Quadro P5000 16GB GDDR5X ai accelerator card
- GDDR5
NVIDIA H200 NVL AI Accelerator Card 141GB HBM3e PCIe 5.0 x16 900-21010-0040-000
- PCI Express 5.0 x16
- NVIDIA