Tripp Lite
Tripp Lite SMART2500XLHG 2200VA 1920W Medical Grade UPS
Medical-grade tower UPS delivers 2200VA/1920W with eight outlets, USB and serial management, and 4.4-minute full-load runtime
- Input Voltage Range120 V AC
- Input ConnectionC20 inlet
- VA Rating2200VA
- Watts1920W
- Output Voltage115V; 120V
- Output Frequency60 Hz
- Medical-grade protection meets UL 60601-1 for patient-care areas
- High 2200VA 1920W capacity powers critical medical equipment
- Eight outlets include 4 NEMA 5-15/20R and 4 IEC C13 receptacles
- USB, DB9 serial, EPO and SNMP slot enable comprehensive remote management
- 4 minutes full-load runtime and 13 minutes half-load runtime with 4.5-hour recharge
Medical Grade UPS for Patient Care
The Tripp Lite SMART2500XLHG is a 2200VA 1920W tower UPS tested to UL60601-1 for use in patient care areas. It delivers battery backup and surge protection for clinical labs, diagnostic imaging and other medical equipment. Eight outlets include four NEMA 5-15/20R and four IEC C13 receptacles.
UL60601-1 Compliance Decides Suitability
The single specification that determines whether this unit fits your installation is its UL60601-1 3rd edition listing. Without this medical grade approval a UPS cannot be deployed inside patient care vicinities. The rating also confirms 510 joules surge suppression and 120 V AC input via a C20 inlet.
Tower Install With Replaceable Battery
The unit sits on a floor or shelf and connects by USB HID, DB9 serial or an optional SNMP card for network management. An emergency power off port and equipotential bonding lug are built in. Runtime is 4.4 minutes at full load or 13 minutes at half load; the VRLA battery pack RBC48V-HGTWR is user replaceable and recharges in 4.5 hours.
Highlights
- Medical-grade protection meets UL 60601-1 for patient-care areas
- High 2200VA 1920W capacity powers critical medical equipment
- Eight outlets include 4 NEMA 5-15/20R and 4 IEC C13 receptacles
- USB, DB9 serial, EPO and SNMP slot enable comprehensive remote management
- 4 minutes full-load runtime and 13 minutes half-load runtime with 4.5-hour recharge
Specifications
| Brand | TRIPP LITE |
|---|---|
| Series | SmartPro |
| Model | SMART2500XLHG |
| Input Voltage Range | 120 V AC |
| Input Connection | C20 inlet |
| VA Rating | 2200VA |
| Watts | 1920W |
| Output Voltage | 115V; 120V |
| Output Frequency | 60 Hz |
| Outlets | 8 |
| Outlet Type | 4 5-15/20R outlet(s); 4 C13 outlet(s) |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Battery Run Time | Full Load Runtime: 4.4 minutes Half Load Runtime: 13 minutes |
| Battery Recharge Time | 4.5 hours MAX (10% to 90% capacity) Internal batteries only |
| Battery Replaceable | RBC48V-HGTWR |
| Alarms | Audible alarm indicates power-failure, overload and low-battery conditions |
| Interface Port | USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface |
| Management Software | PowerAlert |
| Approvals | Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI); Tested to UL60601-1 (medical grade) |
| Surge Energy Rating | 510 Joules |
| Features | Ideal UPS protection for applications in patient-care areas where UL 60601-1 3rd edition listed medical electrical equipment is required Built-in isolation transformer with Faraday shield offers full isolation and removes common mode noise while maintaining full AC surge suppression in all modes Full line isolation prevents shock potential and operational problems in sensitive electronic equipment Provides connected equipment with continuous power during short and long duration loss of commercial power Expandable runtime is available with the addition of one or more external battery |
| Dimensions | 9.72" x 8.90" x 19.09" (H x W x D) |
| Weight | 73.30 lbs. |
| Package Contents | SMART2500XLHG Medical Grade Tower UPS System AC Power Cord (C19 to NEMA5-20P) PowerAlert Software and cabling Warranty information Instruction manual |
| Shipping weight | 43.27 kg |
| Package size | 584 × 406 × 356 mm |
Questions about this item
How long will the 1920 W rating actually keep my equipment running?
At full 1920 W load the internal batteries last 4.4 minutes; at half load they last 13 minutes.
What does the USB HID and DB9 serial interface let me do in practice?
USB HID enables automatic OS shutdown without extra drivers; DB9 serial and the SNMP slot provide network management and emergency power-off control.
What physical space and connections does the tower need to fit and mount?
It uses a C20 inlet for input and provides four NEMA 5-15/20R plus four IEC C13 outlets; an equipotential earth bonding lug and input locking clamp are built in for secure medical-grade installation.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.