We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Tripp Lite

Tripp Lite PDUMNV30HVLX 5.8kW Monitored PDU 20 C13 4 C19

SKU CH-414D-12E1E MPN PDUMNV30HVLX

Delivers monitored 5.8 kW power to 20 C13 and 4 C19 outlets at 200/208/240 V AC

  • TypeConsumer Electronics
  • Input Voltage200V AC 208V AC 240V AC
  • Output Voltage200V AC 208V AC 240V AC
  • FeaturesProduct Name: PDUMNV30HVLX 5/5.8 kW Single-Phase Monitored P
  • Weight11.50 lbs.
  • Monitored power distribution prevents overloads with real-time load tracking
  • 8 kW capacity supports dense rack deployments at 200/208/240 V AC
  • 20 C13 and 4 C19 outlets fit servers and high-draw gear
  • Vertical 0 U form factor preserves rack space for compute
  • TAA-compliant build qualifies for government procurement requirements

Vertical Monitored PDU 5.8kW

This Tripp Lite PDUMNV30HVLX is a single-phase monitored power distribution unit rated at 5.8kW and 5800 VA. It mounts vertically in a rack and provides 20 IEC 60320 C13 outlets plus 4 IEC 60320 C19 outlets. Input and output voltages are 200V, 208V and 240V AC.

Suited for high-density racks needing remote power

It fits data-centre and server-room racks where administrators must track load levels on each circuit. It is not for environments that require only basic unmonitored power strips. It is not for installations that cannot accommodate a vertical 0U form factor.

20 C13 and 4 C19 outlet mix

The combination of twenty C13 and four C19 receptacles determines how many servers and high-draw devices can connect directly. Verify that your equipment cables match these IEC 60320 connector types before purchase.

Highlights

  • Monitored power distribution prevents overloads with real-time load tracking
  • 8 kW capacity supports dense rack deployments at 200/208/240 V AC
  • 20 C13 and 4 C19 outlets fit servers and high-draw gear
  • Vertical 0 U form factor preserves rack space for compute
  • TAA-compliant build qualifies for government procurement requirements

Specifications

BrandTripp Lite
TypeConsumer Electronics
Input Voltage200V AC
208V AC
240V AC
Output Voltage200V AC
208V AC
240V AC
FeaturesProduct Name: PDUMNV30HVLX 5/5.8 kW Single-Phase Monitored PDU
Output Receptacles: 20 x IEC 60320 C13 / 4 x IEC 60320 C19
Power Rating: 5800 VA
Form Factor: Vertical Rackmount
Product Type: PDU
Package Contents:
PDUMNV30HVLX 5/5.8 kW Single-Phase Monitored PDU
Configuration cable
24 x Cable ties
2 x Cord retention brackets
Rack-mounting hardware
PDUMVROTATEBRKT mounting bracket accessory
Owner's manual
Input Receptacles: NEMA L6-30P
Weight11.50 lbs.
Shipping weight6.80 kg
Package size1854 × 152 × 127 mm

Questions about this item

How much heat does the 5.8 kW monitored PDU add to a rack when it runs continuously?

The unit passes through up to 5800 VA at 200 V, 208 V or 240 V AC; its own losses are a small fraction of that load and do not require extra cooling beyond normal rack airflow.

What input plug or cord must I already have to connect this vertical PDU?

The PDU is wired for single-phase 200 V, 208 V or 240 V AC supply; you need a matching facility receptacle and a cord rated for the chosen voltage and 30 A service.

Will the 20 C13 and 4 C19 outlets accept the IEC 60320 cables from my older servers?

Yes — the 20 IEC 60320 C13 and 4 IEC 60320 C19 receptacles are standard, so existing C13 and C19 power cords plug in directly without adapters.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.