Tripp Lite
Tripp Lite PDUMNH30HVAT2 30A 208/240V Monitored PDU 16 C13 2 C19 1 L6-30R 2U Horizontal
A monitored 30A PDU with 19 outlets (16 C13, 2 C19, 1 L6-30R) for 208/240V single-phase power, dual-input redundancy and 2U horizontal rack mounting
- TypeMonitored
- Rack Size2U
- Input Voltage200 - 240V
- Maximum Input Current30A
- Cord Length10 ft
- FeaturesPDU Plug Type: (2) NEMA L6-30P Input Phase: Single-Phase Inp
- Monitored power distribution across 19 outlets for complete rack visibility
- 30 A capacity supports 5.8 kW loads at 208/240 V
- Dual 10 ft input cords connect to separate primary and secondary sources
- 16 C13 plus 2 C19 and 1 L6-30R outlets fit diverse equipment
- 2U horizontal form factor mounts in standard racks or on walls
30 A monitored PDU with automatic transfer switching
This 2U horizontal unit distributes 208 or 240 V single-phase power through nineteen locking outlets. Sixteen IEC 60320 C13 sockets, two C19 sockets and one NEMA L6-30R receptacle serve rack-mounted servers and network gear. Dual 10 ft input cords connect to separate primary and secondary sources for redundancy.
Verify 30 A L6-30 circuits
Your facility must supply two independent 200-240 V circuits each rated for 30 A with NEMA L6-30 receptacles. The PDU occupies 3.50 inches of vertical rack space and extends 12.50 inches deep. Confirm the rack can accept a 17.50 inch wide horizontal mount and that cable routing accommodates the 10 ft input leads.
Passive cooling with network monitoring draws
The unit operates without internal fans so audible noise is negligible in normal use. Internal monitoring electronics consume a small fraction of the 5.8 kW capacity. Metered input current and voltage are reported over RJ-45 Ethernet for remote load tracking.
Highlights
- Monitored power distribution across 19 outlets for complete rack visibility
- 30 A capacity supports 5.8 kW loads at 208/240 V
- Dual 10 ft input cords connect to separate primary and secondary sources
- 16 C13 plus 2 C19 and 1 L6-30R outlets fit diverse equipment
- 2U horizontal form factor mounts in standard racks or on walls
Specifications
| Brand | Tripp Lite |
|---|---|
| Model | PDUMNH30HVAT2 |
| Type | Monitored |
| Rack Size | 2U |
| Input Voltage | 200 - 240V |
| Maximum Input Current | 30A |
| Cord Length | 10 ft |
| Features | PDU Plug Type: (2) NEMA L6-30P Input Phase: Single-Phase Input Cord Details: Set of two inputs connect to separate PRIMARY and SECONDARY power sources Input Cord Length (ft.): 10 Input Cord Length (m): 3.05 Output Receptacles: (16) C13; (2) C19; (1) L6-30R Output Nominal Voltage: 200; 208; 240 Overload Protection: Includes two 20A output circuit breakers; Breaker 1 controls the upper row of 9 outlets (8 C13, 1 C19); Breaker 2 controls the lower row of outlets (8 C13, 1 C19); L6-30R outlet is unbreakered |
| Dimensions | 3.50" x 17.50" x 12.50" |
| Weight | 13.70 lbs. |
| Shipping weight | 8.17 kg |
| Package size | 533 × 432 × 203 mm |
Questions about this item
What outlets are on the PDU and which cables must I supply?
The unit provides 16 IEC 60320 C13, 2 IEC 60320 C19 and 1 NEMA L6-30R outlets. You must provide cables that match those connectors for your devices.
Should I choose the 208 V or 240 V input for my rack?
The PDU accepts 200–240 V single-phase, so it works on either 208 V or 230/240 V supplies without any setting change.
What does the 5.8 kW rating mean for my actual load?
At 240 V the 30 A limit gives about 5.8 kW maximum; at 208 V the same 30 A limit yields roughly 5.0 kW, so plan your connected equipment accordingly.