Tripp Lite
Tripp Lite PDUMNH20HVAT1 PDU 200-240V 20A 8 C13 2 C19 Dual C20 Network Card 1U
A 1U rackmount PDU supplying eight C13 and two C19 outlets at 200-240 V with automatic transfer switching in under 7 ms and a built-in network card for remote monitoring
- TypeAuto-Transfer Switch; Metered; Monitored
- StyleHorizontal
- CertificationsTested to UL62368-1 (USA/Canada), CE (Europe), Class A/EMC (
- Package IncludesPDUMNH20HVAT1 3.8kW Single-Phase ATS/Monitored PDU (2) Detac
- Input Voltage200 - 240V
- Maximum Input Current20A
- Auto-transfer switching under 7 ms keeps equipment running
- Digital ammeter shows real-time load to prevent overloads
- Pre-installed WEBCARDLX enables 24/7 remote monitoring and control
- Eight C13 plus two C19 outlets support 200-240 V devices
- 1U horizontal form factor fits standard rack cabinets
Auto-Transfer Switch PDU for Network Power
This Tripp Lite PDU is a 1U horizontal unit that combines an automatic transfer switch with metered monitoring. It distributes 200-240V power across eight C13 and two C19 outlets. A pre-installed WEBCARDLX network card enables 24/7 remote access for monitoring and control. The unit includes two 12 ft detachable C19 to C20 input cords for dual-source redundancy.
Suits Racks Needing Redundant Power
IT managers running critical servers in 1U spaces gain millisecond switching between primary and secondary feeds plus real-time load data. The digital ammeter provides on-site visibility while the network interface allows off-site management. Facilities without dual power feeds or without network management infrastructure will not use the core ATS and monitoring functions.
Switching Speed Decides Fit For Sensitive Loads
The transfer switch moves from primary to secondary source in under 7 milliseconds to keep connected equipment running without interruption. This speed protects servers and network gear that cannot tolerate a power break. If your hardware requires a faster or slower transfer window, this specification determines whether the PDU matches the requirement.
Highlights
- Auto-transfer switching under 7 ms keeps equipment running
- Digital ammeter shows real-time load to prevent overloads
- Pre-installed WEBCARDLX enables 24/7 remote monitoring and control
- Eight C13 plus two C19 outlets support 200-240 V devices
- 1U horizontal form factor fits standard rack cabinets
Specifications
| Brand | Tripp Lite |
|---|---|
| Model | PDUMNH20HVAT1 |
| Type | Auto-Transfer Switch; Metered; Monitored |
| Style | Horizontal |
| Certifications | Tested to UL62368-1 (USA/Canada), CE (Europe), Class A/EMC (Emissions), NOM (Mexico), RETIE (Columbia), EAC (Russia), RoHS Complaint, TAA Compliant |
| Package Includes | PDUMNH20HVAT1 3.8kW Single-Phase ATS/Monitored PDU (2) Detachable C19 to C20 input cords, 12 ft. (3.7 m) Configuration cable (10) Plug-lock insert sleeves Rack-mounting hardware Owner's manual |
| Input Voltage | 200 - 240V |
| Maximum Input Current | 20A |
| Cord Length | 12 ft |
| Output Voltage | 200; 208; 220; 230; 240 |
| Output Frequency | 50/60Hz |
| Storage Temperature | -30 °C to +50 °C (-22°F to +122°F) |
| Features | Single-Phase 20A ATS PDU Distributes and Monitors Network-Grade Power in Real Time. Switches from Primary to Secondary Power Source in Milliseconds. Pre-Installed WEBCARDLX Network Interface Offers 24/7 Remote Access for Monitoring and Control. Digital Load Meter Helps Prevent Potentially Expensive Overloads. Mounts into 1U of Rack Space. TAA-Compliant for GSA Schedule Purchases. |
| Dimensions | 1.72" x 17.30" x 14.80" |
| Weight | 10.30 lbs. |
| Shipping weight | 7.71 kg |
| Package size | 594 × 528 × 137 mm |
Questions about this item
Does the PDU generate noticeable heat or fan noise when running continuously at 20 A?
The unit has no fan and relies on passive cooling, so it adds virtually no audible noise; heat output scales with the connected load rather than the PDU itself.
What input connections must already be present on the two power sources for the dual C20 inlets to plug in?
Each 12 ft cord ends in a C19 plug, so both sources need matching C20 receptacles rated for 200–240 V at 20 A.
Will the C13 and C19 outlets power older servers that only accept 208 V or 230 V?
Yes, the PDU passes through 200, 208, 220, 230 and 240 V unchanged, so legacy gear rated for any of those voltages works without modification.