We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Tripp Lite

Tripp Lite PDUMH30HV6 5.8kW Metered PDU 16 C13 2 C19 L6-30P 2U

SKU CH-JD4T-G6J1Z MPN PDUMH30HV6

A 2U rack-mount PDU with 16 C13 and 2 C19 outlets, real-time metering and a 1.8 m L6-30P cord for 208/240V power distribution

  • Type5.8kW Single-Phase Metered PDU
  • Rack Size2U
  • StyleRackmount
  • Package IncludesPDUMH30HV6 5.8kW Single-Phase Metered PDU 18 x Plug-lock ins
  • Input Voltage200; 208; 240
  • Maximum Input Current30A
  • Real-time metering balances loads and prevents downtime
  • 16 C13 and 2 C19 outlets power diverse rack equipment
  • Digital ammeter enables on-site load monitoring
  • 8 m cord with NEMA L6-30P connects to 200/208/240V sources
  • Fits 2U rack space with included mounting brackets

Rackmount metered PDU for 2U spaces

The Tripp Lite PDUMH30HV6 is a single-phase metered power distribution unit built for 2U of rack space. It delivers up to 5.8 kW at 240 V and provides 16 C13 and 2 C19 outlets for servers and network gear. A digital ammeter shows real-time current draw so operators can balance loads and spot overload risks before they cause downtime. The unit ships with mounting brackets and 18 plug-lock insert sleeves to secure cables.

Input power and outlet limits to verify

Confirm the site supplies 200 V, 208 V or 240 V single-phase power and a NEMA L6-30P receptacle for the 1.8 m input cord. The PDU draws a maximum of 30 A input, agency de-rated to 24 A continuous, with 20 A overload protection on each breakered bank. Each C19 outlet supports up to 16 A and each C13 outlet up to 12 A. Total output capacity is 5.8 kW at 240 V, 5 kW at 208 V and 4.8 kW at 200 V.

Sustained-load behaviour and monitoring

Under continuous operation the digital ammeter provides on-site load monitoring at 50/60 Hz without relying on external software. The 20 A breakers protect each bank if sustained current exceeds the rated limit, preventing nuisance trips while guarding downstream equipment. Real-time metering lets staff redistribute loads across the 16 C13 and 2 C19 outlets to keep every bank within its 20 A ceiling during prolonged high-demand periods.

Highlights

  • Real-time metering balances loads and prevents downtime
  • 16 C13 and 2 C19 outlets power diverse rack equipment
  • Digital ammeter enables on-site load monitoring
  • 8 m cord with NEMA L6-30P connects to 200/208/240V sources
  • Fits 2U rack space with included mounting brackets

Specifications

BrandTripp Lite
ModelPDUMH30HV6
Type5.8kW Single-Phase Metered PDU
Rack Size2U
StyleRackmount
Package IncludesPDUMH30HV6 5.8kW Single-Phase Metered PDU
18 x Plug-lock insert sleeves
Rack-mounting hardware
Owner’s manual
Input Voltage200; 208; 240
Maximum Input Current30A
Input Connector(s)NEMA L6-30P
Cord Length6 ft
Output Voltage5.8kW (240V), 5kW (208V), 4.8kW (200V) total capacity / 30A max (Agency de-rated to 24A), 20A max per breakered outlet bank; 16A max per C19 outlet; 12A max per C13 outlet
Output Frequency50/60Hz
Output Connector(s)(16) C13; (2) C19
Overload Protection20A
FeaturesSingle-phase PDU allows real-time current metering to ensure proper load balance and detect problems that could cause costly downtime.
16 C13 and 2 C19 208/240V outlets distribute AC power to connected equipment
Digital ammeter for on-site load monitoring helps prevent power overloads
1.8 m cord with NEMA L6-30P single-phase input connects to AC power source
Metered PDU installs in 2U of rack space using the included mounting brackets
Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
Dimensions3.5" x 17.5" x 12.5"
Weight13.7 lbs.
Shipping weight6.21 kg
Package size508 × 406 × 203 mm

Questions about this item

What comes in the box with the PDUMH30HV6 and what must I supply separately?

The package includes the PDU, 18 plug-lock insert sleeves, rack-mounting hardware and an owner's manual. You must provide a compatible 200-240V power source with a NEMA L6-30R receptacle and IEC C13 or C19 cables for your equipment.

How do I decide which input voltage to plan for — 200, 208 or 240 volts?

The unit accepts any of those voltages automatically. At 240V it delivers 5.8 kW total capacity, at 208V it delivers 5 kW and at 200V it delivers 4.8 kW. Choose the voltage that matches your facility supply.

What does the 5.8 kW rating mean for the actual load I can connect?

At 240V the PDU supports up to 5.8 kW total. Agency de-rating limits the input to 24 A, each breakered bank to 20 A, each C19 outlet to 16 A and each C13 outlet to 12 A. Stay within those per-outlet and per-bank limits.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.