We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Tripp Lite

Tripp Lite PDU3MV6L2120 Metered 0U 3-Phase Surge Protector 5.7 kW 48 Outlets NEMA L21-20P

SKU CH-NA4J-0HTRA MPN PDU3MV6L2120

A metered 0U vertical rackmount PDU delivering 5.7 kW across 48 mixed outlets with per-phase current monitoring and a NEMA L21-20P input

  • TypeMetered
  • Rack Size0U
  • StyleVertical rackmount
  • CertificationsTested to UL60950-1 (USA, Canada), NOM (Mexico), Class A (Em
  • Input Voltage208
  • Maximum Input Current16
  • Monitors load per phase with three built-in current meters
  • Distributes 5.7 kW across 48 outlets for dense racks
  • Fits tight spaces using 0U vertical 70-inch form factor
  • Powers mixed gear via C13, C19 and NEMA 5-15/20R outlets
  • Tested to UL60950-1, NOM, Class A and RoHS standards

Metered three-phase PDU

This metered 0U vertical rackmount PDU distributes three-phase 208 V power through 48 outlets. Built-in current meters report input current on each phase continuously. A NEMA L21-20P plug with a six-foot cord connects the unit to the supply.

Suits racks needing mixed C13, C19 and NEMA outlets

IT managers monitoring phase balance in high-density cabinets will benefit from the per-phase readout. Installations that require only single-phase input or fewer than 48 outlets should consider a simpler power strip.

NEMA L21-20P three-phase input

The unit requires a 208 V three-phase source with a NEMA L21-20P receptacle rated for 16 A maximum input current. Without that specific supply connection the PDU cannot be used.

Highlights

  • Monitors load per phase with three built-in current meters
  • Distributes 5.7 kW across 48 outlets for dense racks
  • Fits tight spaces using 0U vertical 70-inch form factor
  • Powers mixed gear via C13, C19 and NEMA 5-15/20R outlets
  • Tested to UL60950-1, NOM, Class A and RoHS standards

Specifications

BrandTripp Lite
ModelPDU3MV6L2120
TypeMetered
Rack Size0U
StyleVertical rackmount
CertificationsTested to UL60950-1 (USA, Canada), NOM (Mexico), Class A (Emissions), ROHS
Input Voltage208
Maximum Input Current16
Input Connector(s)NEMA L21-20P
Cord Length6 ft
Output Voltage208V: C13 and C19 outlets / 120V: NEMA 5-15/20R outlets
Output Frequency60 Hz
Output Watts (VA)5.7kVA total
Output Connector(s)48 total - 36 C13, 6 C19, 6 NEMA 5-15/20R
Operating Relative Humidity0 - 95%
Features5.7kW 3 phase 208/120V Metered Power Distribution Unit / PDU
Set of 3 built-in current meters continuously report input current per phase
Attached NEMA L21-20P 20A (3P+N+E) 208V 3 phase input plug with 6 ft. / 1.8m cord
0U, 70 in. / 178cm vertical form factor supports installation in 2 or 4 post equipment racks
48 total outlets arranged in three single phase output load banks
36 C13 and 6 C19 outlets output 208V
6 NEMA 5-20R outlets output 120V
Included cord retention brackets keep vital network equipment plugged in and continuously powered
Toolless mounting supported in button-mount
Dimensions70" x 1.93" x 2.2"(H x W x D)
Weight12.6 lbs.
Shipping weight6.80 kg
Package size1778 × 102 × 76 mm

Questions about this item

How much power does the metered PDU draw when it runs continuously at its 5.7 kW rating?

The unit distributes up to 5.7 kW across three phases at 208 V with a maximum input current of 16 A per phase; its own metering electronics consume only a few watts, so nearly all rated capacity reaches the 48 outlets.

What input plug and circuit must already be in place for the NEMA L21-20P connection?

A 20 A three-phase 208 V circuit with a matching NEMA L21-20R receptacle is required; the PDU ships with a 6 ft cord and attached L21-20P plug for that outlet.

Will the six NEMA 5-15/20R outlets accept older 5-15P equipment plugs?

Yes, each 5-15/20R receptacle accepts both standard 5-15P and 5-20P plugs, so legacy 120 V gear connects directly without adapters.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.