We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Tripp Lite

Tripp Lite ISOBAR2-6 2-outlet surge protector 6 ft 1410 J

SKU CH-XQ8F-M6J2G MPN ISOBAR2-6

Two-outlet surge protector with 1410-joule rating, 6-foot cord and EMI/RFI filtering up to 80 dB

  • Outlets2
  • Outlets TypeNEMA 5-15R
  • Cord Length6 Feet
  • Output Amperage Capacity12
  • Output Watt Capacity1440 Watts
  • AC Suppression Joule Rating1410 Joules

Outlets 2

  • Two protected outlets with 1410 joules absorb heavy surges
  • Six-foot cord reaches distant sockets without extension leads
  • 1440-watt capacity handles high-draw equipment safely
  • EMI/RFI filter cuts 40 to 80 dB noise for cleaner power
  • UL 1449, 1283, 1363 and cUL certifications confirm safety compliance

Two-Outlet Surge Suppressor

The Tripp Lite ISOBAR2-6 provides two NEMA 5-15R outlets protected by a 1410-joule suppression rating. It handles up to 1440 watts at 12 amps for basic workstation or home-office equipment. The six-foot cord offers flexible placement near a wall receptacle. It is not suited for installations that require more than two protected outlets.

EMI/RFI Filtering and Clamping

A built-in filter attenuates electromagnetic and radio-frequency interference by 40 to 80 decibels across the power line. The sine-wave tracking circuit clamps transient spikes at 140 volts RMS and reduces a 6000-volt test surge to less than 35 volts. The light-grey metal housing measures 2.50 by 9.00 by 3.50 inches and weighs 1.60 pounds. No active cooling is required.

1410-Joule Energy Rating

The single specification that determines suitability is the 1410-joule AC suppression rating, which defines how much surge energy the unit can absorb before protection degrades. Units carry UL1449, UL1283, UL1363 and cUL certifications. The package includes the suppressor, four outlet safety covers and an instruction manual with warranty information. Buyers needing higher joule capacity or additional outlets should select a different model.

Highlights

  • Two protected outlets with 1410 joules absorb heavy surges
  • Six-foot cord reaches distant sockets without extension leads
  • 1440-watt capacity handles high-draw equipment safely
  • EMI/RFI filter cuts 40 to 80 dB noise for cleaner power
  • UL 1449, 1283, 1363 and cUL certifications confirm safety compliance

Specifications

BrandTRIPP LITE
ModelISOBAR2-6
Outlets2
Outlets TypeNEMA 5-15R
Cord Length6 Feet
Output Amperage Capacity12
Output Watt Capacity1440 Watts
AC Suppression Joule Rating1410 Joules
EMI/RFI Noise Filter40 - 80dB
Clamping Voltage140 Volts - RMS
CertificationsUL1449, UL1283, UL1363, cUL
ColorLight Gray
FeaturesRobust surge suppression with sine-wave tracking protects against the heaviest of surge conditions, exceeding IEEE category A&B specifications and reducing 6,000V test surges to harmless levels less than 35 volts
Multi-component suppression circuits combine torroidal chokes, ferrite rod-core inductors, HF/VHF capacitors and multiple layers of metal oxide varistors
2 AC outlets accommodate up to 2 large transformer plugs
Network grade surge suppression rated at 1410 joules/48,000 amps
Widely spaced outlets accommodate up to 2 large transformer plugs without blocking outlets
Lighted po
Unit Dimensions2.50" x 9.00" x 3.50"
Unit Weight1.60 lbs.
Package ContentsISOBAR2-6 Surge Suppressor
Set of 4 outlet safety covers
Instruction manual with warranty information
Shipping weight0.83 kg
Package size273 × 147 × 69 mm

Other versions of this model

4 more in the same range

Same family, different memory, cooler or clock — compare before you commit.

Questions about this item

How do I mount the ISOBAR2-6 and what step is often missed?

Plug the 6 ft cord into a grounded NEMA 5-15R wall receptacle and press the unit onto a flat surface; the step often missed is confirming the outlet is properly earthed so the 1410 joule suppression and 140 V clamping can function.

What part will need replacement after extended use?

The internal metal-oxide varistors absorb surges up to 1410 joules total; once that energy budget is spent the suppressor no longer clamps at 140 V and the whole unit must be replaced.

What limit appears first during a long period of heavy load?

Continuous draw must stay at or below 12 A and 1440 W; exceeding either trips the internal breaker before the 40-80 dB EMI/RFI filter or surge components reach their limits.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.