Tripp Lite
Tripp Lite ECO350UPS 350 VA 180 W UPS
Ultra-compact 350 VA standby UPS delivers 180 W battery backup with three supported outlets, three surge-only ports, USB management and 420-joule protection
- Input Voltage Range120V AC
- Input Connection5-15P; Right-Angled
- VA Rating350 VA
- Watts180 Watts
- Output Voltage115V; 120V 115V (+/- 5%) (Battery Mode)
- Output Frequency60 Hz
VA 350 VA
- 350 VA
- 550 VA
- 750 VA
- 1300 VA / LCD Screen
- 350 VA standby power keeps systems running during outages
- 99% line-mode efficiency cuts UPS consumption below 2 watts
- ECO outlets auto-power peripherals when PC sleeps saving energy
- USB HID port enables unattended shutdown without data loss
- 420-joule surge suppression plus TEL/DSL line protection safeguards gear
Ultra-compact standby UPS
The Tripp Lite ECO350UPS is a 350 VA, 180 W standby uninterruptible power supply for 120 V environments. It delivers 115 V or 120 V output at 60 Hz with 99 % line-mode efficiency. Six NEMA 5-15R outlets provide three battery-backed and three surge-only connections, plus a USB HID port and TEL/DSL line protection.
Home-office and small-desktop users
This unit suits a single workstation, monitor and one essential peripheral that need brief battery runtime to save work and shut down safely. The ECO outlets cut power to idle accessories such as printers or speakers when the PC enters standby. Builders needing extended runtime, higher wattage for gaming rigs, or rack-mount form factors should consider other solutions.
350 VA / 180 W capacity rating
The 350 VA rating defines the maximum apparent power the UPS can supply, while the 180 W limit sets the real-power ceiling for connected equipment. At half load (90 W) the internal VRLA battery provides 11.3 minutes of runtime, enough for an orderly shutdown. Exceeding 180 W will trigger overload alarms and cut output, so total device draw must stay below this figure.
Highlights
- 350 VA standby power keeps systems running during outages
- 99% line-mode efficiency cuts UPS consumption below 2 watts
- ECO outlets auto-power peripherals when PC sleeps saving energy
- USB HID port enables unattended shutdown without data loss
- 420-joule surge suppression plus TEL/DSL line protection safeguards gear
Specifications
| Brand | TRIPP LITE |
|---|---|
| Model | ECO350UPS |
| Input Voltage Range | 120V AC |
| Input Connection | 5-15P; Right-Angled |
| VA Rating | 350 VA |
| Watts | 180 Watts |
| Output Voltage | 115V; 120V 115V (+/- 5%) (Battery Mode) |
| Output Frequency | 60 Hz |
| Outlets | 6 |
| Outlet Type | 5-15R output receptacles (3 UPS supported, 3 surge-only) |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Battery Run Time | Half load runtime: 11.3 min. (90w) |
| Battery Recharge Time | 7 Hour(s) |
| Alarms | Audible alarm indicates power-failure and overload status |
| Interface Port | USB (HID enabled) |
| Approvals | Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI) |
| Data Line Protection | 1 line TEL/DSL (1 in / 1 out) |
| Surge Energy Rating | 420 Joules |
| Features | 350VA ultra-compact 120V standby UPS, energy-saving ECO outlets Maintains AC output during power failures, 99% line mode efficiency ECO option turns off set of two ECO outlets when the computer is not in use USB port, TEL/DSL protection, Wall mountable, Surge-only outlets NEMA 5-15P input plug and 6 NEMA 5-15R outlets |
| Dimensions | 3.00" x 8.00" x 6.40" (H x W x D) |
| Weight | 5.20 lbs. |
| Package Contents | ECO350UPS UPS System USB cable Instruction manual |
| VA | 350 VA |
| Shipping weight | 2.68 kg |
| Package size | 287 × 196 × 104 mm |
Other versions of this model
3 more in the same range
Same family, different memory, cooler or clock — compare before you commit.
Tripp Lite ECO750UPS 750 VA 450 W 12 Outlets UPS
- 120V AC
- NEMA 5-15P; Right-A…
Tripp Lite ECO1300LCD UPS 1300 VA 720 W 10 Outlets USB 120V
- 120V
- NEMA 5-15P
Questions about this item
When will the VRLA battery need replacing?
The sealed lead-acid battery is rated for about 11.3 minutes at half load (90 W) and recharges in 7 hours; typical service life is 3 to 5 years before capacity drops enough to require a new cartridge.
What is the first limit reached during a long outage?
At 180 W maximum the unit will run only a few minutes before the battery is depleted, so runtime is the first constraint under sustained use.
How much heat and noise does it produce when running all day?
In line mode it operates at 99 % efficiency, drawing under 2 W, so heat output is minimal and the unit is fanless and silent until the audible alarm sounds on battery or overload.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Innovation First, Inc. 1UCMA-137 1U Cable Management Arm 19" 28.5"-33" computer accessory
- Product Type:Cable…
- Panel Width:19" Rac…
Vertiv 4UTELECOMRKIT 19 in rack mount bracket accessory
- GXT4U Wall Mount Br…
- Mounting Bracket