We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Tripp Lite

Tripp Lite 9PX6KTF5G2 UPS 6000VA 5400W 120/208V 6U Rack/Tower

SKU CH-AVTP-DV86Q MPN 9PX6KTF5G2

Online double-conversion UPS delivers 6000 VA / 5400 W with 18 NEMA 5-20R, two L6-20R and one L6-30R outlets in a 6U rack/tower chassis

  • VA Rating6000 VA
  • Watts5400 W
  • Output Voltage200 V AC 208 V AC 220 V AC 230 V AC 240 V AC 100 V AC 110 V
  • Output Frequency50 Hz 60 Hz
  • Outlets18 x NEMA 5-20R 2 x NEMA L6-20R 1 x NEMA L6-30R 1 x Hardwire
  • Battery TypeLead Acid Battery
  • Online double-conversion topology protects critical IT loads from all power disturbances
  • 6000 VA and 5400 W capacity supports dense server and networking deployments
  • Hot-swappable VRLA batteries with ABM+ predictive analytics extend service life up to 50%
  • 18 NEMA 5-20R, 2 L6-20R, 1 L6-30R and hardwired outputs enable flexible rack or tower wiring
  • Gigabit network card and USB/RS-232 ports provide secure remote monitoring and management

6 kVA Online UPS for Edge IT

The Eaton 9PX G2 9PX6KTF5G2 delivers 6000 VA and 5400 W of double-conversion power in a 6U rack or tower chassis. It accepts hard-wired or NEMA L6-30P input and provides 120 V, 208 V and other selectable output voltages. Operating range spans 0 to 40 °C with 0 to 95 % non-condensing humidity.

Bundled Transformer and Network Card

A 9PXTFMR5G2 step-down transformer enables 120 V output from the 208 V source. The NETWORK-M3 Gigabit card adds secure remote monitoring over Ethernet. Hot-swappable VRLA batteries can be replaced without shutting down connected loads, and ABM+ charging extends battery service life.

Suits Critical Rack Loads, Not Compact Spaces

This unit fits data-centre racks, edge nodes and server rooms that need scalable runtime and segmented load control. The 203 lb weight and 27 in depth demand sturdy rails or floor space. Buyers needing a smaller footprint or lower power rating should consider alternative form factors.

Highlights

  • Online double-conversion topology protects critical IT loads from all power disturbances
  • 6000 VA and 5400 W capacity supports dense server and networking deployments
  • Hot-swappable VRLA batteries with ABM+ predictive analytics extend service life up to 50%
  • 18 NEMA 5-20R, 2 L6-20R, 1 L6-30R and hardwired outputs enable flexible rack or tower wiring
  • Gigabit network card and USB/RS-232 ports provide secure remote monitoring and management

Specifications

BrandEATON
Series9PX G2
Model9PX6KTF5G2
Part Number9PX6KTF5G2
VA Rating6000 VA
Watts5400 W
Output Voltage200 V AC
208 V AC
220 V AC
230 V AC
240 V AC
100 V AC
110 V AC
120 V AC
Output Frequency50 Hz
60 Hz
Outlets18 x NEMA 5-20R
2 x NEMA L6-20R
1 x NEMA L6-30R
1 x Hardwired
Battery TypeLead Acid Battery
Battery Run TimeBackup/Run Time (Full Load):
3 Minute
Backup/Run Time (Half Load):
8.30 Minute
Battery Recharge Time3 Hour
Battery ReplaceableHot Swappable:
Yes
Replaceable Battery:
Yes
Package Contents9PX G2 9PX6KTF5G2 6000VA Rack/Tower UPS
9PXTFMR5G2 120V Step-down Transformer
NETWORK-M3 Gigabit Network Card
USB Cable
RS-232 Cable
Cable Gland for Hardwire Connection
Rack-mounting Hardware
Tower Support Stands
Quick Start Guide
Shipping weight120.20 kg
Package size978 × 787 × 635 mm

Questions about this item

How often will the hot-swappable VRLA battery modules need replacement under typical use?

ABM+ technology monitors real-world usage and temperature to predict the exact replacement date, extending battery lifespan up to 50% compared with standard charging methods.

At full 5400 W load, how long will the internal batteries keep equipment running before shutdown?

The unit provides 3 minutes of backup at full 5400 W load; at half load the run time extends to 8.30 minutes.

What is the maximum ambient temperature the UPS can operate in continuously without derating?

The UPS is rated for continuous operation up to 40 °C (non-condensing humidity 0-95%).

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.