We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Tripp Lite

Tripp Lite 9PX6KP2G2 6000VA 6000W 208/120V Online UPS

SKU CH-KRPV-74N9V MPN 9PX6KP2G2

Double-conversion UPS delivers 6000 VA and 6000 W to rack or tower IT loads with hardwired input and output, a Gigabit network card and extended battery runtime

  • VA Rating6000 VA
  • Watts6000 W
  • Package Contents9PX G2 9PX6KP2G2 6000VA Rack/Tower UPS 9PXPPDM2G2 PowerPass
  • Online double-conversion topology protects critical loads from all power disturbances
  • 6000 VA / 6000 W capacity supports dense IT racks and edge infrastructure
  • Hardwired input and output with 120 V, 208 V, 240 V selectable voltages
  • Included NETWORK-M3 Gigabit card enables full remote monitoring and control
  • 6U rack/tower form factor fits standard cabinets or stands upright

6000 VA Double-Conversion UPS

The Tripp Lite 9PX6KP2G2 is a 6000 VA, 6000 W online double-conversion UPS designed for distributed IT and edge networks. It accepts hardwired 200 V to 240 V input and delivers selectable 120 V or 208 V output. The unit operates in rack or tower orientation and includes a NETWORK-M3 Gigabit card for remote management.

Hardwired Installation and Environmental Limits

This model requires hardwired input and output connections with no plug-and-play cordset. It operates between 0 and 40 CELSIUS in 0 to 95 percent non-condensing humidity. The 6U chassis measures 17.300 inches wide, 27.000 inches deep and 10.200 inches high, weighing 203 lbs, so adequate rack space and structural support are mandatory.

Extended Runtime for Critical Loads

Standard internal batteries provide limited ride-through; the PowerPass Distribution Module adds maintenance bypass but not extra capacity. Optional extended battery modules are required when outages exceed the base runtime or when loads approach 6000 W. Without those modules the UPS suits only short-duration events such as file saves and graceful shutdowns.

Highlights

  • Online double-conversion topology protects critical loads from all power disturbances
  • 6000 VA / 6000 W capacity supports dense IT racks and edge infrastructure
  • Hardwired input and output with 120 V, 208 V, 240 V selectable voltages
  • Included NETWORK-M3 Gigabit card enables full remote monitoring and control
  • 6U rack/tower form factor fits standard cabinets or stands upright

Specifications

BrandEATON
Model9PX6KP2G2
Part Number9PX6KP2G2
VA Rating6000 VA
Watts6000 W
Package Contents9PX G2 9PX6KP2G2 6000VA Rack/Tower UPS
9PXPPDM2G2 PowerPass Distribution Module with Maintenance Bypass
NETWORK-M3 Gigabit Network Card
USB Cable
RS-232 Cable
Cable Gland for Hardwire Connection
Rack-mounting Hardware
Tower Support Stands
Quick Start Guide
Shipping weight122.02 kg
Package size991 × 743 × 629 mm

Questions about this item

Should I choose the hardwired version or one with standard outlets?

This unit only offers hardwired input and output; there is no version with plug-in receptacles.

What does the 6000 W rating mean for my actual load?

The UPS can supply a continuous 6000 W to connected equipment, matching its 6000 VA rating at unity power factor.

How does the Gigabit network card limit remote management?

The included NETWORK-M3 card provides full remote access and control over a standard 1 Gbps Ethernet link.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.