Telemecanique Sensors
Telemecanique Sensors XY2CH13250H7 Cable Pull Switch
Emergency cable pull switch with maintained function, 10 A thermal rating, 50 ft maximum span and 1NO/1NC contacts
- Emergency stop within 50 ft cable span
- Maintained switch function stays activated until reset
- 10 A thermal rating handles heavy loads
- NEMA 1, 12, 4 enclosure resists dust and water
- Booted push-button reset enables quick restart
Industrial Safety Switch
The Telemecanique Sensors XY2CH13250H7 is a cable pull switch rated at 10 A thermal current for emergency stop circuits on conveyors and production lines. It provides 1NO+1NC contact form with AC rating of 3 A at 240 V and DC rating of 0.27 A at 250 V for direct machine shutdown.
Reset Mechanism and Cable Span
A booted push button reset allows deliberate restart after an emergency pull while resisting dust and moisture ingress. The switch supports a maximum cable span of 50 ft with left or right cable connection and an operating force of 4.5 lb for reliable actuation.
Mounting and Environmental Fit
Single end mounting style suits end-of-line installations on flat surfaces using the Zamak housing dimensions of 7.76 in length, 2.68 in width and 2.38 in depth. NEMA 1, 12 and 4 ratings cover indoor dust, splashing water and hose directed water but not hazardous locations or sub zero environments.
Highlights
- Emergency stop within 50 ft cable span
- Maintained switch function stays activated until reset
- 10 A thermal rating handles heavy loads
- NEMA 1, 12, 4 enclosure resists dust and water
- Booted push-button reset enables quick restart
Specifications
| Brand | TELEMECANIQUE SENSORS |
|---|
Questions about this item
How often should the booted push-button reset be inspected or replaced on the XY2CH13250H7 cable pull switch?
The reset mechanism is built for maintained operation; inspect the boot and button during routine safety audits and replace if the sealing boot shows cracks or the button fails to return cleanly.
What is the maximum cable span the XY2CH13250H7 can handle before the switch may not trip reliably?
The switch is rated for a maximum cable span of 50 ft; exceeding this distance can prevent the mechanism from reaching the required 4.5 lb operating force.
How much heat does the contact block generate when the XY2CH13250H7 runs continuously at its 10 A thermal rating?
At the 10 A thermal rating the contacts are designed to stay within NEMA temperature limits; no additional cooling is required for the Zamak enclosure in normal indoor use.