TAURKENAM
TAURKENAM 1U 8-Outlet PDU Surge 6ft Cord 15A 12A
Distributes 15A power through eight NEMA 5-15R outlets in a 1U horizontal rack-mount with surge protection LEDs and a 6 ft cord
- TypeSee Description
- Delivers 15A (US Listed 12A) through 8 NEMA 5-15R outlets
- Power, Earth and Lightning Protection LEDs show status at a glance
- 1U horizontal profile (19" x 1.7" x 1.7") fits standard 19-inch racks
- Single NEMA 5-15P input connects to common wall circuits
- UL listed for safety compliance in data centres and offices
Power distribution for 1U racks
This 1U horizontal PDU fits a standard 19-inch cabinet and provides eight NEMA 5-15R outlets fed by a single NEMA 5-15P plug. It is built for server rooms, network closets and office racks that need reliable strip power in a single rack unit.
Status LEDs and UL listing
Three front-panel indicators show power, earth continuity and surge-protection status at a glance. The unit carries a UL listing and is rated for 15 A input with a US-listed 12 A continuous limit through the six-foot cord.
Replaces basic strips without monitoring
It upgrades simple power strips that lack surge indication or rack-mount brackets. The jump is worthwhile when you need visible protection status and a secure 1U footprint in a cabinet.
Highlights
- Delivers 15A (US Listed 12A) through 8 NEMA 5-15R outlets
- Power, Earth and Lightning Protection LEDs show status at a glance
- 1U horizontal profile (19" x 1.7" x 1.7") fits standard 19-inch racks
- Single NEMA 5-15P input connects to common wall circuits
- UL listed for safety compliance in data centres and offices
Specifications
| Type | See Description |
|---|
Questions about this item
How do I mount the 1U horizontal PDU in a standard 19-inch rack, and which step is often missed?
Use the included brackets to secure the 19-inch wide unit into a 1U space, then plug the NEMA 5-15P input into a 15A branch circuit; the step often missed is confirming the branch circuit is rated for 15A so the 12A UL listing is not exceeded.
What maintenance does the surge protection require, and when should the unit be replaced?
No user-serviceable parts exist; replace the entire PDU when the red Lightning Protection indicator extinguishes, signalling the surge circuit has sacrificed itself and can no longer clamp transients.
What is the first limit reached when all eight outlets are loaded continuously?
The 12A UL-listed continuous current limit is reached before the 15A plug rating, so total connected draw must stay at or below 12 amperes to avoid nuisance tripping or overheating.