SQUARE D BY SCHNEIDER ELECTRIC
SQUARE D BY SCHNEIDER ELECTRIC BDL36060 60 A 3-pole load center
A 60 A, three-pole molded case circuit breaker rated 525 V AC with a 25 kA interrupting rating at 277/408 V AC, thermal-magnetic trip and EverLink lugs on both ends for unit-mount installation
- Reliable protection with 60 A thermal-magnetic trip
- High fault-current withstand at 25 kA interrupting rating
- Fits standard panels using 125 A frame size
- Simple installation via EverLink lugs on both ends
- Compact footprint measuring 5.39 in height and 3.19 in width
Industrial circuit protection
The Square D BDL36060 is a 60 A three-pole molded case circuit breaker rated for 525 V AC. It provides thermal-magnetic trip protection with a fixed instantaneous setting and a 25 kA interrupting rating at 277/408 V AC. The unit-mount frame fits standard electrical distribution equipment and industrial control panels.
Panel builders and maintenance teams
This breaker suits installations that require a 125 A frame size with EverLink lugs on both ends for secure conductor termination. It is not for systems needing DC voltage ratings, adjustable trip curves, or plug-in mounting styles. Buyers who need a different pole count or a higher AIR rating should look at alternative models.
Verify panel compatibility
Confirm the enclosure accepts a unit-mount device measuring 5.39 in high by 3.19 in wide with ABC phase connection. Ensure the available fault current does not exceed the 25 kA rating at the applied voltage. Check that 525 V AC matches your system voltage and that thermal-magnetic protection meets the coordination study requirements.
Highlights
- Reliable protection with 60 A thermal-magnetic trip
- High fault-current withstand at 25 kA interrupting rating
- Fits standard panels using 125 A frame size
- Simple installation via EverLink lugs on both ends
- Compact footprint measuring 5.39 in height and 3.19 in width
Specifications
| Brand | SQUARE D |
|---|
Questions about this item
What panel rating do I need so the 125 A frame of this BDL36060 fits correctly?
The breaker uses a 125 A frame size; mount it in a panel or enclosure rated for at least that frame.
Will the 25 kA interrupting rating at 277/408 V coordinate with existing downstream breakers?
This unit provides a fixed 25 kA AIR at 277/408 V; verify downstream devices have equal or lower ratings for proper coordination.
How do I confirm the EverLink lugs on both ends are torqued properly after installation?
Torque each EverLink lug to the value printed on the breaker label, then verify no conductor movement and that the thermal-magnetic trip operates on test.