SQUARE D BY SCHNEIDER ELECTRIC
SQUARE D BY SCHNEIDER ELECTRIC BDA36060 60 A 525V AC 3 Pole I-Line load center
Three-pole molded-case circuit breaker rated 60 A at 525 V AC with a 14 kA interrupting rating at 600Y/347 V AC for I-Line load centers
- 60 A three-phase protection for industrial panels
- 525 V AC rating handles heavy-duty distribution loads
- 14 kA interrupting capacity at 600Y/347 V AC
- Thermal-magnetic trip with fixed instantaneous response
- I-Line mounting fits Square D load centres
BDA36060 60 A 525V AC 3 Pole I-Line Breaker
The Square D BDA36060 is a molded case circuit breaker rated 60 A at 525 V AC with a 14 kA interrupting rating at 600Y/347 V AC. It uses a thermal-magnetic trip unit with fixed instantaneous settings and mounts on an I-Line bus. The frame size is 125 A and the breaker stands 5.39 in tall.
Industrial panels needing 60 A three-phase
This breaker suits panels that require a standard 3-pole device with ABC phase connection and Al mechanical lugs on the OFF end. It is not for systems that need DC ratings, adjustable instantaneous trip, or a mounting style other than I-Line. Buyers who need a different pole count or voltage class should look at other models.
60 A 525 V AC rating with 14 kA AIR at 600Y/347 V AC
The single specification that decides fit is the 60 A, 525 V AC rating combined with a 14 kA interrupting rating at 600Y/347 V AC. Verify that your panel’s available fault current and bus voltage match these values before selecting this breaker.
Highlights
- 60 A three-phase protection for industrial panels
- 525 V AC rating handles heavy-duty distribution loads
- 14 kA interrupting capacity at 600Y/347 V AC
- Thermal-magnetic trip with fixed instantaneous response
- I-Line mounting fits Square D load centres
Specifications
| Brand | SQUARE D |
|---|
Questions about this item
Does the BDA36060 ship with the mechanical lug already fitted, or do I need to buy the lug separately?
The breaker is supplied with the Al mechanical lug on the OFF end; the I-Line stab on the ON end is integral and requires no separate accessory.
How do I decide between the 60 A frame and the 125 A frame for my panel?
Choose the 60 A BDA36060 when the circuit load is 60 A or below; the 125 A frame is a larger breaker that occupies the same I-Line slot but is rated for higher current.
What does the 14 kA interrupting rating at 600Y/347 V mean for a 525 V system?
It means the breaker can safely interrupt up to 14 000 A of fault current on a 525 V three-phase supply, since 525 V falls within the 600Y/347 V rating.