Schneider Electric
Schneider Electric T02AN13G7 120VAC 3-pole 9A NEMA Size 00 contactor
A non-reversing magnetic contactor with three poles, 9 A inductive rating and 120 V AC coil for motor control
- Non-reversing operation suits simple motor-start circuits
- 3-pole design switches three-phase loads in one unit
- 120 V AC coil voltage matches standard control supplies
- 9 A inductive rating handles 1.5 hp at 240 V and 2 hp at 480 V
- Screw-clamp terminals give secure field wiring without special tools
Application fit
The Schneider Electric T02AN13G7 is a NEMA Size 00 non-reversing magnetic contactor rated for three-phase motor control. It suits panels that switch 9 A inductive loads at 240 V AC or 480 V AC with a 120 V AC control coil. Builders needing a reversing starter or a different coil voltage must select another device.
Sustained operation
The contactor carries 9 A full-load inductive current continuously and is rated 1-1/2 hp at 240 V AC and 2 hp at 480 V AC three-phase. Its TeSys N series construction uses screw-clamp terminals for secure power wiring. The open-frame design has no enclosure rating, so ambient temperature and ventilation inside the cabinet determine long-term thermal performance.
Installation checks
Verify the control circuit supplies 120 V AC to the coil and that the panel provides at least 3.34 in height by 1.76 in width for the unit. Confirm three-pole wiring matches the motor leads and that the single 1NO/1NC auxiliary contact block satisfies the control logic. Ensure screw-clamp terminals accept the conductor sizes used in the project.
Highlights
- Non-reversing operation suits simple motor-start circuits
- 3-pole design switches three-phase loads in one unit
- 120 V AC coil voltage matches standard control supplies
- 9 A inductive rating handles 1.5 hp at 240 V and 2 hp at 480 V
- Screw-clamp terminals give secure field wiring without special tools
Specifications
| Brand | SCHNEIDER ELECTRIC |
|---|
Questions about this item
How much heat does the 120V AC coil generate when the contactor runs continuously?
The coil is rated for 120V AC operation; continuous energisation produces typical magnetic-coil warmth but no specific heat-dissipation figure is published for this NEMA Size 00 unit.
What control-circuit wiring and supply must I already have to operate the 120V AC coil?
You need a 120V AC control source and conductors sized for the coil’s inrush and sealed current, terminated on the screw-clamp terminals provided.
Will the 9A inductive rating and 1-1/2 hp at 240V / 2 hp at 480V three-phase match the motor I already use?
The contactor handles 9A inductive loads with 1-1/2 hp at 240V AC and 2 hp at 480V AC three-phase; verify your motor’s full-load amps and voltage against those ratings.